Articles with "insulated switchgear" as a keyword



Photo by maxwbender from unsplash

On the management of metallic particle contamination in gas insulated switchgear

Sign Up to like & get
recommendations!
Published in 2017 at "IEEE Transactions on Dielectrics and Electrical Insulation"

DOI: 10.1109/tdei.2017.006179

Abstract: Electrical insulation performance of compressed gas insulated switchgear (GIS) is adversely affected by metallic particle contaminants with a loss of up to 90% of the gas dielectric strength. Such particles play a crucial role in… read more here.

Keywords: metallic particle; gas; insulated switchgear; insulation ... See more keywords
Photo from wikipedia

The Study on a New Method for Detecting Corona Discharge in Gas Insulated Switchgear

Sign Up to like & get
recommendations!
Published in 2022 at "IEEE Transactions on Instrumentation and Measurement"

DOI: 10.1109/tim.2021.3129225

Abstract: Partial discharge (PD) is the main cause of insulation deterioration and failure of gas-insulated switchgear (GIS). Corona discharge (CD) is a typical type of PD in gas-insulated switchgear. Accurate and sensitive measurement of CD in… read more here.

Keywords: gas insulated; discharge; insulated switchgear; method ... See more keywords
Photo from wikipedia

An Elimination Method for an Emergency Situation in Gas-Insulated Switchgear in Power Grids

Sign Up to like & get
recommendations!
Published in 2021 at "IEEE Transactions on Power Delivery"

DOI: 10.1109/tpwrd.2020.3048789

Abstract: This paper presents the possibilities of reducing emergency situations and reducing the time of failure in the power grid. The paper contains a detailed description of the method (algorithm) of operation in emergency situations on… read more here.

Keywords: paper; power; insulated switchgear; emergency ... See more keywords
Photo from wikipedia

Status Review on Gas Insulated Switchgear Partial Discharge Diagnostic Technique for Preventive Maintenance

Sign Up to like & get
recommendations!
Published in 2017 at "Indonesian Journal of Electrical Engineering and Computer Science"

DOI: 10.11591/ijeecs.v7.i1.pp9-17

Abstract: Gas insulated switchgear (GIS) plays a vital role in high voltage transmission of electrical energy due to its advantages of high reliability and performance, compact in dimensions and outstanding compatibility with the environment. It uses… read more here.

Keywords: preventive maintenance; gas; insulated switchgear; gas insulated ... See more keywords