Sign Up to like & get
recommendations!
1
Published in 2021 at "Graefe's Archive for Clinical and Experimental Ophthalmology"
DOI: 10.1007/s00417-020-05046-3
Abstract: The aim of this study was to compare the visual and refractive outcomes of total keratometry (TK) versus anterior keratometry (AK) measurements of the IOLMaster 700® (Carl Zeiss Meditec AG, Jena, Germany) in surgery for…
read more here.
Keywords:
keratometry;
refractive outcomes;
keratometry versus;
total keratometry ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2019 at "Journal of cataract and refractive surgery"
DOI: 10.1016/j.jcrs.2019.08.010
Abstract: PURPOSE To compare refractive outcomes of eyes with flat keratometry (K) to matched controls after myopic laser in situ keratomileusis (LASIK). SETTING Boston Eye Group, Brookline, Massachusetts, USA. DESIGN Retrospective review. METHODS Eyes that had LASIK…
read more here.
Keywords:
calculated postoperative;
keratometry;
cdva;
corrected distance ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2020 at "Eye"
DOI: 10.1038/s41433-020-01245-8
Abstract: Objectives We aimed (1) to assess the repeatability of Total Keratometry (TK) and standard keratometry (K) measurements, as provided by the IOLMaster 700 (Carl Zeiss Meditec), and (2) to compare the corneal astigmatism measured by…
read more here.
Keywords:
keratometry;
group;
repeatability total;
corneal astigmatism ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "Journal of cataract and refractive surgery"
DOI: 10.1097/j.jcrs.0000000000000974
Abstract: PURPOSE To evaluate the agreement in biometry measurements and Intraocular lens (IOL) power calculations between two integrated swept-source-optical coherence tomography (SS-OCT) tomography/biometry devices: the Eyestar 900 (Haag-Streit Diagnostics, Koeniz, Switzerland) and the Anterion (Heidelberg Engineering,…
read more here.
Keywords:
agreement;
eyestar 900;
power calculations;
iol power ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "Optometry and Vision Science"
DOI: 10.1097/opx.0000000000001307
Abstract: SIGNIFICANCE This is a prospective observational investigation that studies the repeatability of several outcomes obtained with the Keratron Scout in healthy and keratoconic corneas. In addition, we have been able to determine the "noise" values…
read more here.
Keywords:
keratometry;
keratoconic eyes;
repeatability;
healthy keratoconic ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2020 at "BioMed Research International"
DOI: 10.1155/2020/8075924
Abstract: Purpose The relationship between conventional keratometry and total keratometry has not been fully investigated. This study was aimed at conventional keratometry measured with the automated keratometer and total keratometry with the corneal tomographer in ophthalmologically…
read more here.
Keywords:
keratometry;
keratometry total;
tnp;
power ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2022 at "Frontiers in Medicine"
DOI: 10.3389/fmed.2022.928027
Abstract: Background More recently, the swept-source OCT biometer-IOLMaster 700 has provided direct total corneal power measurement, named total keratometry. This study aims to evaluate whether standard keratometry (SK) and total keratometry (TK) with IOLMaster 700 can…
read more here.
Keywords:
corneal refractive;
surgery;
corneal;
myopic corneal ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
2
Published in 2023 at "Journal of refractive surgery"
DOI: 10.3928/01913913-20230125-01
Abstract: PURPOSE To compare the influence of total keratometry (TK) versus anterior keratometry (K) measured with the swept-source optical biometer IOLMaster 700 (Carl Zeiss Meditec AG) on the planning of toric intraocular lenses (IOLs), and the…
read more here.
Keywords:
anterior keratometry;
error;
total keratometry;
keratometry ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2019 at "Journal of refractive surgery"
DOI: 10.3928/1081597x-20190422-02
Abstract: PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation based on standard keratometry (K) and the new Total Keratometry (TK). METHODS A post-hoc analysis of study data based on 145 pseudophakic astigmatic eyes…
read more here.
Keywords:
versus barrett;
barrett universal;
ape;
barrett ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2019 at "Journal of refractive surgery"
DOI: 10.3928/1081597x-20190903-01
Abstract: PURPOSE To evaluate the safety and efficacy of accelerated contact lens-assisted cross-linking (A-CACXL) for patients with keratoconus and thin corneas. METHODS This retrospective study included consecutive patients undergoing A-CACXL for progressive keratoconus from 2015 to…
read more here.
Keywords:
minimum corneal;
corneal;
corneal thickness;
contact lens ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2022 at "Saudi Journal of Ophthalmology"
DOI: 10.4103/sjopt.sjopt_138_21
Abstract: PURPOSE: The purpose of the study is to evaluate the comparability of corneal power measurements, anterior chamber depth (ACD), and white-to-white (WTW) distance between a high-resolution Scheimpflug-based tomography (Pentacam HR; Oculus GmbH, Wetzlar, Germany) and…
read more here.
Keywords:
source optical;
surgery;
scheimpflug based;
swept source ... See more keywords