Articles with "keratometry" as a keyword



Photo by papaioannou_kostas from unsplash

Impact of measured total keratometry versus anterior keratometry on the refractive outcomes of the AT TORBI 709-MP toric intraocular lens

Sign Up to like & get
recommendations!
Published in 2021 at "Graefe's Archive for Clinical and Experimental Ophthalmology"

DOI: 10.1007/s00417-020-05046-3

Abstract: The aim of this study was to compare the visual and refractive outcomes of total keratometry (TK) versus anterior keratometry (AK) measurements of the IOLMaster 700® (Carl Zeiss Meditec AG, Jena, Germany) in surgery for… read more here.

Keywords: keratometry; refractive outcomes; keratometry versus; total keratometry ... See more keywords
Photo by nate_dumlao from unsplash

The effect of low predicted/calculated postoperative keratometry on corrected distance visual acuity after LASIK.

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of cataract and refractive surgery"

DOI: 10.1016/j.jcrs.2019.08.010

Abstract: PURPOSE To compare refractive outcomes of eyes with flat keratometry (K) to matched controls after myopic laser in situ keratomileusis (LASIK). SETTING Boston Eye Group, Brookline, Massachusetts, USA. DESIGN Retrospective review. METHODS Eyes that had LASIK… read more here.

Keywords: calculated postoperative; keratometry; cdva; corrected distance ... See more keywords

Repeatability of total Keratometry and standard Keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging

Sign Up to like & get
recommendations!
Published in 2020 at "Eye"

DOI: 10.1038/s41433-020-01245-8

Abstract: Objectives We aimed (1) to assess the repeatability of Total Keratometry (TK) and standard keratometry (K) measurements, as provided by the IOLMaster 700 (Carl Zeiss Meditec), and (2) to compare the corneal astigmatism measured by… read more here.

Keywords: keratometry; group; repeatability total; corneal astigmatism ... See more keywords
Photo by mbrunacr from unsplash

Comparison of Two Novel Integrated Swept-source.

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of cataract and refractive surgery"

DOI: 10.1097/j.jcrs.0000000000000974

Abstract: PURPOSE To evaluate the agreement in biometry measurements and Intraocular lens (IOL) power calculations between two integrated swept-source-optical coherence tomography (SS-OCT) tomography/biometry devices: the Eyestar 900 (Haag-Streit Diagnostics, Koeniz, Switzerland) and the Anterion (Heidelberg Engineering,… read more here.

Keywords: agreement; eyestar 900; power calculations; iol power ... See more keywords
Photo by marina_mv08 from unsplash

Repeatability of Anterior Curvature Metrics in Healthy and Keratoconic Eyes with a Portable Handheld Topographer.

Sign Up to like & get
recommendations!
Published in 2018 at "Optometry and Vision Science"

DOI: 10.1097/opx.0000000000001307

Abstract: SIGNIFICANCE This is a prospective observational investigation that studies the repeatability of several outcomes obtained with the Keratron Scout in healthy and keratoconic corneas. In addition, we have been able to determine the "noise" values… read more here.

Keywords: keratometry; keratoconic eyes; repeatability; healthy keratoconic ... See more keywords
Photo by ry4nolson from unsplash

Comparison of Conventional Keratometry and Total Keratometry in Normal Eyes

Sign Up to like & get
recommendations!
Published in 2020 at "BioMed Research International"

DOI: 10.1155/2020/8075924

Abstract: Purpose The relationship between conventional keratometry and total keratometry has not been fully investigated. This study was aimed at conventional keratometry measured with the automated keratometer and total keratometry with the corneal tomographer in ophthalmologically… read more here.

Keywords: keratometry; keratometry total; tnp; power ... See more keywords
Photo from wikipedia

Comparing Standard Keratometry and Total Keratometry Before and After Myopic Corneal Refractive Surgery With a Swept-Source OCT Biometer

Sign Up to like & get
recommendations!
Published in 2022 at "Frontiers in Medicine"

DOI: 10.3389/fmed.2022.928027

Abstract: Background More recently, the swept-source OCT biometer-IOLMaster 700 has provided direct total corneal power measurement, named total keratometry. This study aims to evaluate whether standard keratometry (SK) and total keratometry (TK) with IOLMaster 700 can… read more here.

Keywords: corneal refractive; surgery; corneal; myopic corneal ... See more keywords
Photo from wikipedia

Total Keratometry Measured With a Swept-Source Optical Biometer Versus Anterior Keratometry: From Planning to Postoperative Results.

Sign Up to like & get
recommendations!
Published in 2023 at "Journal of refractive surgery"

DOI: 10.3928/01913913-20230125-01

Abstract: PURPOSE To compare the influence of total keratometry (TK) versus anterior keratometry (K) measured with the swept-source optical biometer IOLMaster 700 (Carl Zeiss Meditec AG) on the planning of toric intraocular lenses (IOLs), and the… read more here.

Keywords: anterior keratometry; error; total keratometry; keratometry ... See more keywords
Photo from wikipedia

Prediction Accuracy of Total Keratometry Compared to Standard Keratometry Using Different Intraocular Lens Power Formulas.

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of refractive surgery"

DOI: 10.3928/1081597x-20190422-02

Abstract: PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation based on standard keratometry (K) and the new Total Keratometry (TK). METHODS A post-hoc analysis of study data based on 145 pseudophakic astigmatic eyes… read more here.

Keywords: versus barrett; barrett universal; ape; barrett ... See more keywords
Photo from wikipedia

Corneal Cross-linking in Thin Corneas: 1-Year Results of Accelerated Contact Lens-Assisted Treatment of Keratoconus.

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of refractive surgery"

DOI: 10.3928/1081597x-20190903-01

Abstract: PURPOSE To evaluate the safety and efficacy of accelerated contact lens-assisted cross-linking (A-CACXL) for patients with keratoconus and thin corneas. METHODS This retrospective study included consecutive patients undergoing A-CACXL for progressive keratoconus from 2015 to… read more here.

Keywords: minimum corneal; corneal; corneal thickness; contact lens ... See more keywords
Photo from wikipedia

Agreement between swept-source optical biometry and Scheimpflug-based tomography in eyes with previous myopic refractive surgery

Sign Up to like & get
recommendations!
Published in 2022 at "Saudi Journal of Ophthalmology"

DOI: 10.4103/sjopt.sjopt_138_21

Abstract: PURPOSE: The purpose of the study is to evaluate the comparability of corneal power measurements, anterior chamber depth (ACD), and white-to-white (WTW) distance between a high-resolution Scheimpflug-based tomography (Pentacam HR; Oculus GmbH, Wetzlar, Germany) and… read more here.

Keywords: source optical; surgery; scheimpflug based; swept source ... See more keywords