Sign Up to like & get
recommendations!
0
Published in 2017 at "Strategies in Trauma and Limb Reconstruction"
DOI: 10.1007/s11751-017-0293-7
Abstract: Clavicle fractures are common, accounting for 2.6 to 10% of all fractures. Treatment of these fractures is usually non-surgical. Recent evidence, however, reveals that the final result of non-surgically midshaft clavicular fractures, particularly those with…
read more here.
Keywords:
clavicle fractures;
treatment;
kirschner wire;
threaded kirschner ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2019 at "Revista Brasileira de Ortopedia"
DOI: 10.1016/j.rbo.2017.09.017
Abstract: The use of metal wires, called Kirschner wires, is a simple and effective fixation method for the correction of shoulder fractures and of dislocations in orthopedic surgery. Wire migration during the postoperative follow-up is a…
read more here.
Keywords:
wire migration;
shoulder;
migration;
kirschner wire ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2017 at "Clinical Spine Surgery"
DOI: 10.1097/bsd.0000000000000254
Abstract: Study Design: A retrospective study. Objective: To assess the safety and efficacy of iliac crest defect reconstruction using Kirschner wire (K-wire)/polymethylmethacrylate (PMMA) versus traditional autologous rib graft reconstruction. Summary of Background Data: The iliac crest…
read more here.
Keywords:
reconstruction;
strut bone;
graft;
wire ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2019 at "Medicine"
DOI: 10.1097/md.0000000000017498
Abstract: Abstract This study aimed to compare the efficacy and safety among Kirschner wire, anatomical plate fixation and cannulated screw treatments in patients with open calcaneal fractures, and to explore the predictive factors for treatment response…
read more here.
Keywords:
cannulated screw;
plate fixation;
fixation;
anatomical plate ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "BioMed Research International"
DOI: 10.1155/2018/5017162
Abstract: We investigate the clinical efficacy of Kirschner wire temporary intramedullary fixation combined with a locking anatomical plate for the treatment of comminuted clavicular fractures. We retrospectively studied 112 patients [80 (71%) men] treated between February…
read more here.
Keywords:
fixation combined;
intramedullary fixation;
kirschner wire;
plate ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2023 at "Journal of orthopaedic surgery"
DOI: 10.1177/10225536231175235
Abstract: PURPOSE Biomechanical study of fixation methods post hallux valgus minimally invasive osteotomy using finite element technology hasn't been reported. This study aimed to compare maximum displacement and stress distribution of osteotomy ends after minimally invasive…
read more here.
Keywords:
invasive osteotomy;
osteotomy;
hallux valgus;
kirschner wire ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2020 at "Scandinavian Journal of Surgery"
DOI: 10.1177/1457496920908770
Abstract: Background and Aims: Lateral-only Kirschner-wire pinning of supracondylar humerus fracture is superior in avoiding surgery-related ulnar nerve injury. Their disadvantageous effects on stability may be a consequence of inappropriate surgical techniques. We analyzed whether the…
read more here.
Keywords:
fixation;
lateral kirschner;
kirschner wire;
type ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "BMC Surgery"
DOI: 10.1186/s12893-024-02382-7
Abstract: Skier’s thumb is a type of injury to the ulnar collateral ligament of the metacarpophalangeal joint of the thumb, which can result in bone fragmentation and joint instability. The objective of this study was to…
read more here.
Keywords:
shaped kirschner;
skier thumb;
wire;
kirschner wire ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2023 at "A&A practice"
DOI: 10.1213/xaa.0000000000001679
Abstract: We report the successful management of a difficult airway in an extremely low birth weight neonate (700 g) using a Kirschner wire as a substitute for an endotracheal tube stylet. Several intubation attempts were unsuccessful because…
read more here.
Keywords:
report;
kirschner wire;
management difficult;
using kirschner ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "PLOS ONE"
DOI: 10.1371/journal.pone.0302839
Abstract: Purposes Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor…
read more here.
Keywords:
wire tension;
cross stitch;
tension band;
kirschner wire ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2025 at "Frontiers in Pediatrics"
DOI: 10.3389/fped.2025.1636165
Abstract: Objective The aims of this study were to review our cases of missed Monteggia fracture treated by open reduction of the radial head with or without ulnar osteotomy and to investigate the necessity of ulnar…
read more here.
Keywords:
missed monteggia;
ulnar osteotomy;
group;
kirschner wire ... See more keywords