Sign Up to like & get
recommendations!
1
Published in 2017 at "BMJ Case Reports"
DOI: 10.1136/bcr-2016-217834
Abstract: Inadvertent knotting of infant feeding tubes used for clean intermittent catheterisation (CIC) is a rare complication in paediatric patients. The small flexible tubes used in infants if advanced too far into the bladder may form…
read more here.
Keywords:
catheter;
twist tail;
urethral catheter;
catheter twist ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "BMJ Case Reports"
DOI: 10.1136/bcr-2017-221498
Abstract: Knotting of feeding tubes or urinary catheters has been reported as a rare complication in paediatrics when draining the bladder. This is caused by inserting thin flexible tubes too far in, allowing it to coil.…
read more here.
Keywords:
catheter;
urethral catheter;
complication;