Articles with "kvp" as a keyword



Photo from wikipedia

Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients?

Sign Up to like & get
recommendations!
Published in 2018 at "European Radiology"

DOI: 10.1007/s00330-018-5850-z

Abstract: ObjectiveTo investigate the image quality and radiation dose of dual-energy computed tomography (DECT) with automatic spectral imaging protocol selection (ASIS) compared with those of low-kVp CT in abdominal multiphase CT.MethodsFour groups of 60 patients each… read more here.

Keywords: image; contrast; kvp; kvp images ... See more keywords
Photo from wikipedia

A LESSON FROM AUTOMATIC TUBE VOLTAGE SELECTION: FEASIBILITY OF 100 kVp IN PORTAL VENOUS PHASE ABDOMINAL CT.

Sign Up to like & get
recommendations!
Published in 2020 at "Radiation protection dosimetry"

DOI: 10.1093/rpd/ncz302

Abstract: PURPOSE To evaluate the relationship between ATVS-recommended tube voltage and patient body habitus and to compare radiation dose and diagnostic performance between fixed 120-kVp and ATVS protocols in portal venous phase abdomen CT. METHODS A… read more here.

Keywords: tube voltage; venous phase; kvp; portal venous ... See more keywords
Photo from wikipedia

Hepatic dual-contrast CT imaging: slow triple kVp switching CT with CNN-based sinogram completion and material decomposition

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Medical Imaging"

DOI: 10.1117/1.jmi.9.1.014003

Abstract: Abstract. Purpose: Dual-contrast protocols are a promising clinical multienergy computed tomography (CT) application for focal liver lesion detection and characterization. One avenue to enable multienergy CT is the introduction of photon-counting detectors (PCD). Although clinical… read more here.

Keywords: kvp switching; kvp; dual contrast; decomposition ... See more keywords
Photo from wikipedia

Variation in tube voltage for pediatric neck 64VCT: Effect on radiation dose and image quality

Sign Up to like & get
recommendations!
Published in 2021 at "PLoS ONE"

DOI: 10.1371/journal.pone.0259772

Abstract: Exposure to ionizing radiation can cause cancer, especially in children. In computed tomography (CT), a trade-off exists between the radiation dose and image quality. Few studies have investigated the effect of dose reduction on image… read more here.

Keywords: image; image quality; neck; kvp ... See more keywords
Photo from wikipedia

Coronary artery calcium score scan at 100 kVp with tin filtration (Sn100 kVp) prior to coronary computed tomography angiography for overall radiation dose reduction: a prospective cohort study

Sign Up to like & get
recommendations!
Published in 2022 at "Quantitative Imaging in Medicine and Surgery"

DOI: 10.21037/qims-21-1129

Abstract: Background Reducing radiation dose is a global concern in coronary computed tomography angiography (CCTA). We aimed to investigate whether a coronary artery calcium score (CACS) scan would lead to an overall reduction of radiation dose… read more here.

Keywords: kvp; computed tomography; ccta; radiation dose ... See more keywords
Photo from wikipedia

High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium

Sign Up to like & get
recommendations!
Published in 2017 at "Korean Journal of Radiology"

DOI: 10.3348/kjr.2017.18.5.763

Abstract: Objective To evaluate the feasibility and image quality (IQ) of prospectively high-pitch coronary CT angiography (CCTA) with low contrast medium injection rate at 70 kVp. Materials and Methods One hundred and four patients with suspected… read more here.

Keywords: contrast; kvp; rate; injection ... See more keywords
Photo by usgs from unsplash

Deep Learning-Based Reconstruction vs. Iterative Reconstruction for Quality of Low-Dose Head-and-Neck CT Angiography with Different Tube-Voltage Protocols in Emergency-Department Patients

Sign Up to like & get
recommendations!
Published in 2022 at "Diagnostics"

DOI: 10.3390/diagnostics12051287

Abstract: Objective: To compare the image quality of computed tomography angiography of the supra-aortic arteries (CTSA) at different tube voltages in low doses settings with deep learning-based image reconstruction (DLR) vs. hybrid iterative reconstruction (H-IR). Methods:… read more here.

Keywords: image quality; quality; kvp; reconstruction ... See more keywords