Articles with "laboratory ray" as a keyword



Flexible and Transparent Ceramic Nanocomposite for Laboratory X-ray Imaging of Micrometer Resolution.

Sign Up to like & get
recommendations!
Published in 2022 at "ACS nano"

DOI: 10.1021/acsnano.2c10531

Abstract: Transparent nanocomposites have attracted considerable attention in many areas including X-ray imaging, wearable electronics, and volumetric display. However, both the transparency and the flexibility were largely jeopardized by the loading content of functional nanoparticles (NPs),… read more here.

Keywords: laboratory ray; ray; film; resolution ... See more keywords

CO2 and H2O Sorption Induced Bulk-Phase Changes of CALF-20 Captured Using In Situ Laboratory X‑ray Powder Diffraction

Sign Up to like & get
recommendations!
Published in 2025 at "Journal of the American Chemical Society"

DOI: 10.1021/jacs.5c06866

Abstract: The zinc oxalate (ox) triazolate (trz)-based MOF, Calgary Framework 20 (CALF-20), exhibits remarkable cycling stability for carbon dioxide and water adsorption and desorption and is therefore a promising candidate material for CO2 sequestration on an… read more here.

Keywords: co2 h2o; laboratory ray; ray powder; powder diffraction ... See more keywords

Detailed simulation and characterization of double paraboloidal monocapillary for laboratory X-ray sources

Sign Up to like & get
recommendations!
Published in 2025 at "Chinese Physics B"

DOI: 10.1088/1674-1056/addcc3

Abstract: A double-parabola monocapillary (DPM) was designed for laboratory x-ray sources, and its performance was evaluated through numerical simulations and experimental validation. A surface shape error model was developed to characterize the DPM surface profile, and… read more here.

Keywords: simulation characterization; ray sources; simulation; detailed simulation ... See more keywords

Laboratory x-ray nano-computed tomography for biomedical research

Sign Up to like & get
recommendations!
Published in 2024 at "Journal of Instrumentation"

DOI: 10.1088/1748-0221/19/10/p10021

Abstract: High-resolution x-ray tomography is a common technique for biomedical research using synchrotron sources. With advancements in laboratory x-ray sources, an increasing number of experiments can be performed in the lab. In this paper, the design,… read more here.

Keywords: contrast; ray nano; nano computed; biomedical research ... See more keywords

Laboratory X-ray astrophysics at ultrabrilliant light sources with PolarX-EBIT

Sign Up to like & get
recommendations!
Published in 2025 at "Journal of Instrumentation"

DOI: 10.1088/1748-0221/20/03/c03030

Abstract: The x-ray spectra recorded with high-resolution spectrometers onboard satellite observatories contain valuable information about a wide range of different hot astrophysical environments. However, our ability to extract this information is currently often limited by the… read more here.

Keywords: astrophysics; light sources; polarx ebit; highly charged ... See more keywords