Articles with "lcl type" as a keyword



Photo by danedeaner from unsplash

Improved Current Decoupling Method for Robustness Improvement of LCL-type STATCOM Based on Active Disturbance Rejection Control

Sign Up to like & get
recommendations!
Published in 2019 at "IEEE Access"

DOI: 10.1109/access.2019.2931747

Abstract: When theoretically studying the control method of LCL-type static synchronous compensator (STATCOM), we often ignore the influence of complex power grid on the stability and reactive compensation performance of STATCOM. Improving traditional current decoupling method… read more here.

Keywords: method; current decoupling; decoupling method; statcom ... See more keywords

Harmonic Instability of LCL-Type Grid-Connected Inverter Caused by the Pole-Zero Cancellation: A Case Study

Sign Up to like & get
recommendations!
Published in 2022 at "IEEE Transactions on Industrial Electronics"

DOI: 10.1109/tie.2021.3123616

Abstract: Pole-zero cancellation technique has drawn much attention to tackle the filter resonance of the LCL-type grid-connected inverter for simplifying the stability-oriented design. However, its potential stability risk was rarely concerned. As one representative of this… read more here.

Keywords: lcl type; zero cancellation; pole zero; type grid ... See more keywords
Photo by kellysikkema from unsplash

Passivity-Based Stabilization of LCL-Type Grid-Connected Inverters via a General Admittance Model

Sign Up to like & get
recommendations!
Published in 2020 at "IEEE Transactions on Power Electronics"

DOI: 10.1109/tpel.2019.2955861

Abstract: For LCL-type grid-connected inverters, inverter-side current, grid-side current, capacitor current and voltage are four commonly used variables in the control serving as different roles, such as control objective, active damping, synchronization, etc. This article builds… read more here.

Keywords: type grid; passivity; lcl type; admittance ... See more keywords
Photo by stayandroam from unsplash

Analysis of an LCL-T Type Resonant Dc–Dc Converter by the Fundamental Harmonic Method

Sign Up to like & get
recommendations!
Published in 2019 at "Russian Electrical Engineering"

DOI: 10.3103/s1068371219080030

Abstract: Abstract—The approximate expressions for calculating currents at an inverter’s output and at the input of the output rectifier, as well as the efficiency and load characteristics of a dc–dc converter, are obtained on the basis… read more here.

Keywords: lcl type; harmonic method; fundamental harmonic; converter ... See more keywords