Leadless pacemaker through tricuspid bioprosthetic valve: Early experience

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of Arrhythmia"

DOI: 10.1002/joa3.12478

Abstract: Leadless pacemaker (LP) therapy has been proved effective in cases where traditional transvenous right pacing (TRP) failed. TRP through a bioprosthetic tricuspid valve (BTV) has always been considered an unpreferable solution because of possible deleterious… read more here.

Keywords: tricuspid bioprosthetic; pacemaker tricuspid; leadless; bioprosthetic valve ... See more keywords

State of the art: leadless ventricular pacing

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Interventional Cardiac Electrophysiology"

DOI: 10.1007/s10840-019-00680-2

Abstract: Background Cardiac pacing has been shown to improve quality of life and prognosis of patients with bradycardia for almost 60 years. The latest innovation in pacemaker therapy was miniaturization of generators to allow leadless pacing directly… read more here.

Keywords: leadless pacing; leadless ventricular; leadless; pacing systems ... See more keywords

Intraoperative sensing increase predicts long-term pacing threshold in leadless pacemakers

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Interventional Cardiac Electrophysiology"

DOI: 10.1007/s10840-021-01111-x

Abstract: Purpose High pacing threshold (HPT) and very high pacing threshold (VHPT) are known to have a negative impact on leadless pacemaker battery longevity, representing the most common reason for device repositioning. In this study, we… read more here.

Keywords: wave sensing; intraoperative sensing; pacing threshold; month ... See more keywords
Photo from wikipedia

Syncope after successful implantation of atrioventricular synchronous leadless pacemaker caused by polymorphic ventricular tachycardia

Sign Up to like & get
recommendations!
Published in 2020 at "HeartRhythm Case Reports"

DOI: 10.1016/j.hrcr.2020.05.003

Abstract: Introduction Leadless pacing is an alternative to transvenous single-chamber ventricular pacing (VVI/R) with a favorable safety and efficacy profile in selected patients. Until recently, the Micra (Model MC1VR01; Medtronic Inc, Minneapolis, MN) was the only… read more here.

Keywords: ventricular tachycardia; polymorphic ventricular; leadless; implantation ... See more keywords
Photo from wikipedia

Synchronization of the new leadless transcatheter pacing system with a transvenous atrial pacemaker: A case report

Sign Up to like & get
recommendations!
Published in 2020 at "HeartRhythm Case Reports"

DOI: 10.1016/j.hrcr.2020.08.014

Abstract: Introduction Permanent cardiac pacing has afforded immense benefit and treatment to millions of patients who have suffered from bradyarrhythmias. Since its inception, cardiac implantable electronic devices (CIED) were limited to subcutaneously implanted generatorswith 1 ormore… read more here.

Keywords: atrial pacemaker; pacemaker; leadless; transvenous atrial ... See more keywords

Leadless cardiac resynchronization therapy: An in vivo proof-of-concept study of wireless pacemaker synchronization.

Sign Up to like & get
recommendations!
Published in 2019 at "Heart rhythm"

DOI: 10.1016/j.hrthm.2019.01.010

Abstract: BACKGROUND Contemporary leadless pacemakers (PMs) only feature single-chamber ventricular pacing. However, the majority of patients require dual-chamber pacing or cardiac resynchronization therapy (CRT). Several leadless PMs implanted in the same heart would make that possible… read more here.

Keywords: communication; leadless; resynchronization therapy; cardiac resynchronization ... See more keywords

Monocentric experience of leadless pacing with focus on challenging cases for conventional pacemaker

Sign Up to like & get
recommendations!
Published in 2018 at "Acta Cardiologica"

DOI: 10.1080/00015385.2017.1410351

Abstract: Abstract Aim: Leadless cardiac pacemaker has been developed to reduce complications related to cardiac pacing and is considered as an alternative to conventional pacemaker although safety and efficacy data in clinical practice are limited. The… read more here.

Keywords: cases conventional; pacemaker; leadless; conventional pacemaker ... See more keywords

Device longevity of a leadless pacemaker family

Sign Up to like & get
recommendations!
Published in 2025 at "Future Cardiology"

DOI: 10.1080/14796678.2025.2527466

Abstract: ABSTRACT Background Leadless ventricular pacemakers have been developed for single chamber VVIR and AV synchronous pacing applications. Aim To assess the device longevity impact of battery/electronics enhancements of next-generation Micra leadless pacemakers, Micra VR2 and… read more here.

Keywords: pacemaker; micra vr2; device; leadless ... See more keywords

Safety profile, electrical performances and clinical outcomes of a novel leadless pacemaker; first results from real-world clinical practice in Saudi Arabia

Sign Up to like & get
recommendations!
Published in 2024 at "European Heart Journal"

DOI: 10.1093/eurheartj/ehae666.707

Abstract: Leadless pacemakers (LP) are emerging as an effective and safe alternative to transvenous pacemakers to reduce lead-related and pocket-related complications and to improve patient experience. A new LP system, the Aveir VR, has been approved… read more here.

Keywords: pacemaker; safety; leadless; performances clinical ... See more keywords

New generation of LCPM and left atrial strain: a promising predictor of atrio-ventricular synchrony in leadless pacemaker pacing

Sign Up to like & get
recommendations!
Published in 2023 at "Europace"

DOI: 10.1093/europace/euad122.352

Abstract: Abstract Funding Acknowledgements Type of funding sources: None. Introduction Leadless cardiac pacemakers (LCPMs) are a new alternative to traditional transvenous pacemaker. They recently have evolved from a single chamber VVI-R pacemaker to devices that can… read more here.

Keywords: lcpm; atrial strain; strain; left atrial ... See more keywords
Photo by ldxcreative from unsplash

Leadless pacemaker implantation following transvenous lead extraction: data from i-LEAPER registry

Sign Up to like & get
recommendations!
Published in 2023 at "Europace"

DOI: 10.1093/europace/euad122.483

Abstract: Abstract Funding Acknowledgements Type of funding sources: None. Background transvenous (TV) pacemakers are negatively associated with local and systemic device-related infections, often requiring transvenous lead extraction (TLE). Moreover, patients reimplanted with a TV device following… read more here.