Articles with "lens density" as a keyword



Photo by nmcinteer from unsplash

Association of lens density quantified by IOLMaster 700 with lenticular myopia in nuclear cataract

Sign Up to like & get
recommendations!
Published in 2022 at "Graefe's Archive for Clinical and Experimental Ophthalmology"

DOI: 10.1007/s00417-021-05495-4

Abstract: Purpose To explore the associated ocular parameters with lenticular myopia and assess the correlation between lens density and myopic shift. Methods This retrospective cross-sectional study enrolled 50 patients with lenticular high myopia as the study… read more here.

Keywords: iolmaster 700; quantified iolmaster; lenticular myopia; lens density ... See more keywords
Photo from wikipedia

Impact of lens density and lens thickness on cumulative dissipated energy in femtosecond laser–assisted cataract surgery

Sign Up to like & get
recommendations!
Published in 2019 at "Lasers in Medical Science"

DOI: 10.1007/s10103-019-02715-6

Abstract: To evaluate the required cumulative dissipated energy (CDE) to fragment the crystalline lens in femtosecond laser–assisted cataract surgery (FLACS) in relation to lens density and lens thickness. Consecutive eyes that underwent FLACS between September 2014… read more here.

Keywords: dissipated energy; energy; lens density; femtosecond laser ... See more keywords
Photo from wikipedia

An objective evaluation of crystalline lens density using Scheimpflug lens densitometry in different uveitis entities

Sign Up to like & get
recommendations!
Published in 2020 at "International Ophthalmology"

DOI: 10.1007/s10792-020-01379-4

Abstract: Aim To measure lens densities with a Pentacam HR device in patients with active uveitis. Measurements were taken at the onset of the attack and after the treatment of inflammation. Methods The study included 51… read more here.

Keywords: lens density; objective evaluation; value; lens densitometry ... See more keywords

Correlation Between Lens Density Measured by Swept-Source Optical Coherence Tomography and Phacodynamic Parameters of Centurion Phacoemulsification.

Sign Up to like & get
recommendations!
Published in 2023 at "Current eye research"

DOI: 10.1080/02713683.2023.2192896

Abstract: PURPOSE To evaluate the correlation between lens density measured by IOL-Master 700 based on swept-source optical coherence tomography (SS-OCT) technology and the phacodynamic parameters of Centurion phacoemulsification in cataract surgery. METHODS This prospective study included… read more here.

Keywords: density; phacodynamic parameters; parameters centurion; correlation lens ... See more keywords
Photo by harpreetkaka from unsplash

Useful Prediction of Phacodynamics by Scheimpflug Lens Densitometry in Patients over Age 70

Sign Up to like & get
recommendations!
Published in 2017 at "Seminars in Ophthalmology"

DOI: 10.3109/08820538.2015.1120756

Abstract: ABSTRACT Purpose: To evaluate the relationship between lens density using the Scheimpflug system and phacodynamics in nuclear cataracts as related to patient age. Methods: In 262 eyes with nuclear cataracts, the objective lens density was… read more here.

Keywords: scheimpflug lens; locs iii; patients age; lens density ... See more keywords