Articles with "line field" as a keyword



Photo from wikipedia

Line-field confocal optical coherence tomography as a tool for three-dimensional in vivo quantification of healthy epidermis: a pilot study.

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of biophotonics"

DOI: 10.1002/jbio.202100236

Abstract: Epidermal three-dimensional (3D) topography/quantification have not been completely characterized yet. The recently developed line-field confocal optical coherence tomography (LC-OCT) provides real-time, high-resolution, in-vivo 3D imaging of the skin. This pilot study aimed at quantifying epidermal… read more here.

Keywords: three dimensional; optical coherence; field confocal; study ... See more keywords
Photo from wikipedia

High speed parallel spectral-domain OCT using spectrally encoded line-field illumination

Sign Up to like & get
recommendations!
Published in 2018 at "Applied Physics Letters"

DOI: 10.1063/1.5017078

Abstract: We report parallel spectral-domain optical coherence tomography (OCT) at 500 000 A-scan/s. This is the highest-speed spectral-domain (SD) OCT system using a single line camera. Spectrally encoded line-field scanning is proposed to increase the imaging speed in… read more here.

Keywords: line; spectral domain; line field; speed ... See more keywords
Photo from wikipedia

Line-Field Swept-Source Interferometer for Simultaneous Measurement of Thickness and Refractive Index Distribution

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of Lightwave Technology"

DOI: 10.1109/jlt.2016.2605300

Abstract: We present a novel method for simultaneous measurement of the thickness and refractive index distribution of a transparent specimen by a line-field swept-source interferometer. In this study, by illuminating with the line-field beam instead of… read more here.

Keywords: line; line field; swept source; distribution ... See more keywords
Photo from wikipedia

Scan-Less, Kilo-Pixel, Line-Field Confocal Phase Imaging with Spectrally Encoded Dual-Comb Microscopy

Sign Up to like & get
recommendations!
Published in 2019 at "IEEE Journal of Selected Topics in Quantum Electronics"

DOI: 10.1109/jstqe.2018.2879017

Abstract: Confocal laser microscopy (CLM) is a powerful tool in life science research and industrial inspection, and its image acquisition rate is boosted by scan-less imaging techniques. However, optical-intensity-based image contrast in CLM makes it difficult… read more here.

Keywords: comb; microscopy; line field; field confocal ... See more keywords
Photo from wikipedia

Line‐field confocal optical coherence tomography for the diagnosis of nodular scabies mimicking breast cancer skin metastasis

Sign Up to like & get
recommendations!
Published in 2022 at "International Journal of Dermatology"

DOI: 10.1111/ijd.16457

Abstract: of traction alopecia in at-risk cultural groups other than AfricanAmerican patients. Thus, clinicians must recognize that traction alopecia may commonly develop in other cultural groups as well and provide preventative counseling accordingly. Due to the… read more here.

Keywords: field confocal; cultural groups; confocal optical; traction alopecia ... See more keywords
Photo from wikipedia

Line‐field confocal optical coherence tomography for the in vivo real‐time diagnosis of different stages of keratinocyte skin cancer: a preliminary study

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of the European Academy of Dermatology and Venereology"

DOI: 10.1111/jdv.17603

Abstract: The treatment of keratinocyte cancers (KC) strictly depends on their differentiation and invasiveness. Non‐invasive diagnostic techniques can support the diagnosis in real time, avoiding unnecessary biopsies. This study aimed to preliminarily define main imaging criteria… read more here.

Keywords: optical coherence; field confocal; real time; confocal optical ... See more keywords
Photo from wikipedia

Line‐field confocal optical coherence tomography of basosquamous carcinoma: a case series with histopathological correlation

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of the European Academy of Dermatology and Venereology"

DOI: 10.1111/jdv.18038

Abstract: Basosquamous carcinoma (BSC) is a rare and potentially aggressive cutaneous neoplasm combining histopathological features of basal cell carcinoma (BCC) and squamous cell carcinoma (SCC). Line‐field confocal optical coherence tomography (LC‐OCT) is a new, non‐invasive imaging… read more here.

Keywords: field confocal; confocal optical; line field; basosquamous carcinoma ... See more keywords
Photo from wikipedia

Line‐field confocal optical coherence tomography of psoriasis, eczema and lichen planus: a case series with histopathological correlation

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of the European Academy of Dermatology and Venereology"

DOI: 10.1111/jdv.18293

Abstract: Line‐field confocal optical coherence tomography (LC‐OCT) is a novel, non‐invasive technique that provides in vivo, high‐resolution images in both vertical and horizontal sections. read more here.

Keywords: field confocal; optical coherence; confocal optical; line field ... See more keywords
Photo from wikipedia

Comparison of reflectance confocal microscopy and line‐field optical coherence tomography for the identification of keratinocyte skin tumours

Sign Up to like & get
recommendations!
Published in 2022 at "Skin Research and Technology"

DOI: 10.1111/srt.13215

Abstract: Reflectance confocal microscopy (RCM) and line‐field confocal optical coherence tomography (LC‐OCT) are non‐invasive imaging devices that can help in the clinical diagnosis of actinic keratosis (AK) and cutaneous squamous cell carcinoma (SCC). No studies are… read more here.

Keywords: microscopy; reflectance confocal; coherence tomography; line field ... See more keywords
Photo from wikipedia

Utilizing deep learning for dermal matrix quality assessment on in vivo line‐field confocal optical coherence tomography images

Sign Up to like & get
recommendations!
Published in 2022 at "Skin Research and Technology"

DOI: 10.1111/srt.13221

Abstract: Line‐field confocal optical coherence tomography (LC‐OCT) is an imaging technique providing non‐invasive “optical biopsies” with an isotropic spatial resolution of ∼1  μm and deep penetration until the dermis. Analysis of obtained images is classically performed by… read more here.

Keywords: field confocal; quality; confocal optical; line field ... See more keywords
Photo from wikipedia

Ultra-fast dynamic line-field optical coherence elastography.

Sign Up to like & get
recommendations!
Published in 2021 at "Optics letters"

DOI: 10.1364/ol.435278

Abstract: In this work, we present an ultra-fast line-field optical coherence elastography system (LF-OCE) with an 11.5 MHz equivalent A-line rate. The system was composed of a line-field spectral domain optical coherence tomography system based on… read more here.

Keywords: optical coherence; line field; line; ultra fast ... See more keywords