Sign Up to like & get
recommendations!
1
Published in 2017 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.12080
Abstract: Abstract Purpose The purpose of this guideline is to provide a list of critical performance tests in order to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance…
read more here.
Keywords:
medical physics;
linear accelerator;
performance tests;
physics ... See more keywords
Photo by nci from unsplash
Sign Up to like & get
recommendations!
0
Published in 2017 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.12160
Abstract: Abstract The accurate delivery of respiratory‐gated volumetric modulated arc therapy (VMAT) treatment plans presents a challenge since the gantry rotation and collimator leaves must be repeatedly stopped and set into motion during each breathing cycle.…
read more here.
Keywords:
gated vmat;
linear accelerator;
versa linear;
rate ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2022 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.13587
Abstract: Abstract Purpose/Objective(s) Whole brain radiotherapy with hippocampal avoidance (HA‐WBRT) is a technique utilized to treat metastatic brain disease while preserving memory and neurocognitive function. We hypothesized that the treatment planning and delivery of HA‐WBRT plans…
read more here.
Keywords:
brain;
linear accelerator;
radiotherapy;
mri ... See more keywords
Photo by nci from unsplash
Sign Up to like & get
recommendations!
0
Published in 2019 at "Strahlentherapie und Onkologie"
DOI: 10.1007/s00066-019-01563-1
Abstract: Osteoarthritis is a common disease, with a prevalence of symptomatic disease of 8.9%. One treatment option is radiotherapy. Most published samples were treated with an orthovoltage technique or with a telecobalt device. A lot of…
read more here.
Keywords:
linear accelerator;
radiotherapy osteoarthritis;
treatment;
radiotherapy ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "Clinical and Translational Radiation Oncology"
DOI: 10.1016/j.ctro.2022.02.006
Abstract: Highlights • Scalp-angiosarcoma is difficult to manage, and surgery is the primary therapy.• BNCT can deliver highly effective particles more selectively to tumor cells.• BNCT requires a high neutron flux that typically can only be…
read more here.
Keywords:
accelerator based;
neutron;
scalp angiosarcoma;
treated linear ... See more keywords
Photo by nci from unsplash
Sign Up to like & get
recommendations!
0
Published in 2018 at "Gynecologic Oncology Reports"
DOI: 10.1016/j.gore.2018.05.007
Abstract: Objective The use of SRS and fSRT to determine overall survival, tumor control, and local-disease free progression in patient diagnosed with gynecologic brain metastasis. Methods In this retrospective review, 11 patients aged 50 to 85…
read more here.
Keywords:
secondary gynecologic;
linear accelerator;
accelerator based;
brain metastasis ... See more keywords
Photo by nci from unsplash
Sign Up to like & get
recommendations!
0
Published in 2017 at "Neurologia"
DOI: 10.1016/j.nrl.2015.10.003
Abstract: INTRODUCTION An overview of the effectiveness of radiosurgery in patients diagnosed with trigeminal neuralgia with an analysis of potential predictors of good outcome. METHODS All patients treated with linear accelerator radiosurgery between 2004 and 2011…
read more here.
Keywords:
linear accelerator;
trigeminal neuralgia;
bni score;
radiosurgery ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "Radiation Physics and Chemistry"
DOI: 10.1016/j.radphyschem.2017.04.008
Abstract: Abstract The aim of this study is to evaluate the methacrylic acid, gelatin and tetrakis (hydroxymethyl) phosphonium chloride gel (MAGAT) by cone beam computed tomography (CBCT) attached with modern linear accelerator. To compare the results…
read more here.
Keywords:
cbct attached;
study;
linear accelerator;
gel ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2017 at "World neurosurgery"
DOI: 10.1016/j.wneu.2017.04.081
Abstract: BACKGROUND Linear accelerator stereotactic radiosurgery is one of the modalities available for the treatment of central nervous system arteriovenous malformations (AVMs). The aim of this study was to describe our 15-year experience with this technique…
read more here.
Keywords:
system;
obliteration;
analysis;
year ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2017 at "Measurement Science and Technology"
DOI: 10.1088/1361-6501/aa6c8a
Abstract: Bunch length measurements in electron LINear ACcelerator (LINAC) can be carried out by means of a disruptive optical technique based on a Radio Frequency Deflector (RFD). This device provides a vertical kick to the electrons…
read more here.
Keywords:
length;
bunch length;
measurement;
linear accelerator ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2019 at "Physics in medicine and biology"
DOI: 10.1088/1361-6560/ab4916
Abstract: Shielding protocols such as NCRP 151, IAEA SRS 47 and IPEM 47 are commonly used for the design of radiotherapy facilities. Some work has been accomplished in updating the basic formula with the advent of…
read more here.
Keywords:
stereotactic radiotherapy;
shielding stereotactic;
bunker;
radiotherapy ... See more keywords