Articles with "locking plates" as a keyword



Photo from wikipedia

Primary screw perforation or subsequent screw cut-out following proximal humerus fracture fixation using locking plates: a review of causative factors and proposed solutions

Sign Up to like & get
recommendations!
Published in 2017 at "International Orthopaedics"

DOI: 10.1007/s00264-017-3652-6

Abstract: The surgical treatment of proximal humerus fractures remains controversial primarily due to the high complication rate associated with the available fixation methods. In an attempt to reduce the incidence of serious complications and subsequent poor… read more here.

Keywords: fixation; fracture; proximal humerus; primary screw ... See more keywords
Photo from wikipedia

A comparison of bone union and complication rates between locking and non-locking plates in distal fibular fracture: Retrospective study of 106 cases.

Sign Up to like & get
recommendations!
Published in 2019 at "Injury"

DOI: 10.1016/j.injury.2019.10.001

Abstract: BACKGROUND Ankle fractures represents the third most frequent fracture in elderly patients. There is a current tendency to fix long bones fractures with locking plates. However, we rarely find published accounts about the use of… read more here.

Keywords: fracture; bone union; locking plates; non locking ... See more keywords
Photo from wikipedia

Interprosthetic femoral fractures managed with modern distal femoral locking plates: 10 years' experience at a UK major trauma centre.

Sign Up to like & get
recommendations!
Published in 2021 at "Injury"

DOI: 10.1016/j.injury.2021.04.014

Abstract: INTRODUCTION Interprosthetic femoral fractures (IFF) are rare but increasing with an ageing population. Operative management is challenging and there is currently a paucity of outcome data in literature. The purpose of this study was to… read more here.

Keywords: interprosthetic femoral; femoral fractures; locking plates; modern distal ... See more keywords
Photo from wikipedia

A clinico-radiological study of bicondylar tibial plateau fractures managed with dual locking plates.

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of clinical orthopaedics and trauma"

DOI: 10.1016/j.jcot.2021.101563

Abstract: Background Treatment of bicondylar intra-articular tibial plateau fractures due to high energy trauma is complex and highly prone to complications due to fracture patterns and extensive soft tissue damage. Aim The study's objective was to… read more here.

Keywords: tibial plateau; locking plates; study; dual locking ... See more keywords
Photo from wikipedia

The outcome of surgical management of proximal humeral fractures using locking plates: comparison between locking plates with different geometry.

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of shoulder and elbow surgery"

DOI: 10.1016/j.jse.2018.05.033

Abstract: BACKGROUND Locking plate fixation appears to be a standard treatment for proximal humeral fracture. Different locking plate designs might result in different radiographic and functional outcomes. The original version of the Proximal Humeral Internal Locking… read more here.

Keywords: system; locking plates; geometry; zplp ... See more keywords
Photo by papaioannou_kostas from unsplash

Intra-articular calcaneal fractures. Do locking plates keep the reduction better than conventional plates?

Sign Up to like & get
recommendations!
Published in 2019 at "Revista espanola de cirugia ortopedica y traumatologia"

DOI: 10.1016/j.recot.2019.05.003

Abstract: INTRODUCTION Since the development of locking plates, calcaneal fractures have been considered ideal for this type of fixation, due to the need to maintain the height of the subastragaline joint after depression fractures in a… read more here.

Keywords: reduction; locking plates; group; calcaneal fractures ... See more keywords
Photo from wikipedia

Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures.

Sign Up to like & get
recommendations!
Published in 2017 at "Injury"

DOI: 10.1016/s0020-1383(17)30653-8

Abstract: INTRODUCTION Unstable intra articular fractures of distal radius are frequently being managed with open reduction and internal fixation. Volar locking plate based on polyetheretherketon (PEEK) polymer has developed lately as an alternative to conventional metallic… read more here.

Keywords: radius fractures; locking plates; group; volar locking ... See more keywords
Photo from wikipedia

Efficacy comparison of intramedullary nails, locking plates and conservative treatment for displaced proximal humeral fractures in the elderly

Sign Up to like & get
recommendations!
Published in 2017 at "Clinical Interventions in Aging"

DOI: 10.2147/cia.s144084

Abstract: Purpose The incidence of proximal humeral fractures is high in the elderly, and the superior management of these fractures remains a controversy. The study aims to compare clinical outcomes of intramedullary nails, locking plates and… read more here.

Keywords: part; locking plates; group; humeral fractures ... See more keywords
Photo from wikipedia

Locking plate osteosynthesis in geriatric shoulder fractures: why do we continue to perform a low-value procedure?

Sign Up to like & get
recommendations!
Published in 2022 at "Acta Orthopaedica"

DOI: 10.2340/17453674.2022.2208

Abstract: © 2022 The Author(s). Published by Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/),… read more here.

Keywords: osteosynthesis; non surgical; locking plate; surgical treatment ... See more keywords

Monofilament Cerclage Wiring Fixation with Locking Plates for Distal Femoral Fracture: Is it Appropriate?

Sign Up to like & get
recommendations!
Published in 2019 at "Indian Journal of Orthopaedics"

DOI: 10.4103/ortho.ijortho_269_18

Abstract: Purpose: We aimed to determine the efficacy of cerclage wiring by comparing the clinical and radiological results between internal fixation with locking plates after distal femoral fracture reduction with or without cerclage wiring. Materials and… read more here.

Keywords: fixation; distal femoral; cerclage wiring; locking plates ... See more keywords
Photo from wikipedia

A comparison of distal femoral locking plates for distal femur fractures: Long working length versus short working length.

Sign Up to like & get
recommendations!
Published in 2022 at "JPMA. The Journal of the Pakistan Medical Association"

DOI: 10.47391/jpma.3577

Abstract: OBJECTIVE To compare long working length distal femoral locking plates with short working length for treating extra-articular distal femur fractures in terms of union and implant failure. METHODS The randomised controlled trial was conducted at… read more here.

Keywords: long working; group; short working; locking plates ... See more keywords