Articles with "loop recorder" as a keyword



Photo from wikipedia

Analysis of the determining factors of detectable P‐wave and amplitude of QRS complex sensed by implantable loop recorder

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of Arrhythmia"

DOI: 10.1002/joa3.12582

Abstract: Determining factors for sufficient QRS amplitude and discernible P‐wave sensing in implantable loop recorder (ILR) are unknown. We aimed to investigate determining factors and ILR implantation angle that may improve QRS complex and P‐wave sensing… read more here.

Keywords: determining factors; loop recorder; implantable loop; qrs complex ... See more keywords
Photo from wikipedia

Clinical characteristics associated with bradycardia and asystole in patients with syncope undergoing long-term electrocardiographic monitoring with implantable loop recorder

Sign Up to like & get
recommendations!
Published in 2017 at "Wiener klinische Wochenschrift"

DOI: 10.1007/s00508-017-1197-8

Abstract: SummaryBackgroundThe aim of this retrospective single center cohort study was to assess the occurrence of bradycardia during implantable loop recorder (ILR) monitoring in patients with unexplained syncope and negative conventional testing and to identify clinical… read more here.

Keywords: implantable loop; pacemaker implantation; loop recorder; bradycardia asystole ... See more keywords
Photo by apchf from unsplash

The implantable loop recorder and its mammographic appearance: A case based approach.

Sign Up to like & get
recommendations!
Published in 2017 at "Clinical imaging"

DOI: 10.1016/j.clinimag.2017.01.006

Abstract: The normal radiographic appearance of implantable loop recorders has been illustrated in the radiology literature; however, their mammographic appearance has not been described. Breast imagers should become familiar with the appearance of loop recorders in… read more here.

Keywords: mammographic appearance; implantable loop; recorder mammographic; loop recorder ... See more keywords
Photo from wikipedia

Self-terminating ventricular fibrillation recorded by an implantable loop recorder as a cause of syncope - A case report.

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of electrocardiology"

DOI: 10.1016/j.jelectrocard.2018.04.006

Abstract: Ventricular fibrillation (VF) is the most common arrhythmia leading to sudden cardiac death, but in rare cases VF can manifest as a syncope, provided that it will self-terminate. We present a case of a 45-year… read more here.

Keywords: implantable loop; loop recorder; syncope; cause syncope ... See more keywords
Photo from wikipedia

Implantable loop recorder follow-up

Sign Up to like & get
recommendations!
Published in 2021 at "European Heart Journal"

DOI: 10.1093/eurheartj/ehab724.0318

Abstract: Long ambulatory ECG monitoring can be a useful component in the evaluation of the patient with unexplained syncope or syncope with suspected arrhythmic origin, as well as a sensitive tool for detecting asymptomatic spontaneous cardiac… read more here.

Keywords: loop recorder; unexplained syncope; block; implantable loop ... See more keywords
Photo from wikipedia

Cardiac rhythm recorded by implanted loop recorder during lightning strike

Sign Up to like & get
recommendations!
Published in 2017 at "Annals of Saudi Medicine"

DOI: 10.5144/0256-4947.2017.401

Abstract: Lightning strikes cause severe injuries and fatalities. Injuries vary from self-limiting skin manifestations to cardiac arrest and death. Because the event is sudden and unpredictable, assessment of the direct effects of the lightning on the… read more here.

Keywords: loop recorder; strike; cardiac rhythm; implanted loop ... See more keywords
Photo by apchf from unsplash

Early and late asystole after loop recorder implantation: Misdiagnoses and unexpected diagnostic opportunities

Sign Up to like & get
recommendations!
Published in 2023 at "Cardiology Journal"

DOI: 10.5603/cj.2023.0012

Abstract: An 84-year-old (case 1) and a 79-year-old patient (case 2) were implanted with a Medtronic Reveal LINQ™ in the context of an unexplained syncope of suspected arrhythmic origin. read more here.

Keywords: late asystole; recorder implantation; asystole loop; early late ... See more keywords
Photo from wikipedia

In older patients at high risk for stroke, intensive AF screening with an implantable loop recorder did not reduce stroke

Sign Up to like & get
recommendations!
Published in 2022 at "Annals of Internal Medicine"

DOI: 10.7326/j21-0011

Abstract: SOURCE CITATION Svendsen JH, Diederichsen SZ, Højberg S, et al. Implantable loop recorder detection of atrial fibrillation to prevent stroke (The LOOP Study): a randomised controlled trial. Lancet. 2021;398:1507-16. 34469766. read more here.

Keywords: high risk; loop recorder; implantable loop; older patients ... See more keywords