Sign Up to like & get
recommendations!
1
Published in 2022 at "ASAIO Journal"
DOI: 10.1097/mat.0000000000001651
Abstract: The importance of experimental setups able to reproduce cardiac functions was well established in the field of clinical innovations. The mock circulatory loops acquired rising relevance, and the possibility to have a complete reproduction of…
read more here.
Keywords:
mock circulatory;
patient specific;
analysis;
pump ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "IEEE Transactions on Biomedical Engineering"
DOI: 10.1109/tbme.2022.3156963
Abstract: Objective: This paper presents preliminary methods of incorporating the pathological conditions of cardiac arrhythmias and valvular stenosis in hybrid mock circulation loop (hMCL) operation for the enhanced verification and validation of mechanical circulatory support devices…
read more here.
Keywords:
valvular stenosis;
mock circulatory;
mock;
hybrid mock ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "IEEE Transactions on Biomedical Engineering"
DOI: 10.1109/tbme.2022.3224581
Abstract: Goal: This work presents the development of a Hybrid Mock Circulatory Loop (HMCL) to simulate hemodynamics at patient-specific level in terms of both 3D geometry and inlet/outlet boundary conditions. Methods: Clinical data have been processed…
read more here.
Keywords:
mock circulatory;
patient specific;
hybrid mock;
circulatory loop ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Artificial Organs"
DOI: 10.1111/aor.12809
Abstract: A realistic mock circulatory system (MCS) could be a valuable in vitro testbed to study human circulatory hemodynamics. The objective of this study was to design a MCS replicating the pulmonary arterial circulation, incorporating an…
read more here.
Keywords:
system;
model;
circulatory system;
hemodynamics ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "Artificial organs"
DOI: 10.1111/aor.14433
Abstract: INTRODUCTION Mock circulatory loops (MCLs) are mechanical representations of the cardiovascular system largely used to test the hemodynamic performance of cardiovascular medical devices (MD). Thanks to 3 dimensional (3D) printing technologies, MCLs can nowadays also…
read more here.
Keywords:
circulatory loops;
loops cardiac;
mock circulatory;
anatomical models ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2020 at "Applied Sciences"
DOI: 10.3390/app10165433
Abstract: This study presents a design and evaluation of a mock circulatory platform, which can reproduce blood pressure and its waveforms to provide palpation experience based on the human cardiovascular physiology. To reproduce the human cardiovascular…
read more here.
Keywords:
circulatory platform;
physiology;
platform;
cardiovascular physiology ... See more keywords