Articles with "multi electrode" as a keyword



Photo from archive.org

Multi-electrode Harmonized Kingdon Traps

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of The American Society for Mass Spectrometry"

DOI: 10.1007/s13361-018-2032-9

Abstract: AbstractBased on the analysis of the results of the study of various designs of multi-electrode harmonized Kingdon traps, we propose a new type of trap with two merged internal electrodes that has the ability to… read more here.

Keywords: kingdon traps; electrode harmonized; multi electrode; harmonized kingdon ... See more keywords
Photo from wikipedia

Multi-electrode bioelectrochemical system for the treatment of high total dissolved solids bearing chemical based wastewater.

Sign Up to like & get
recommendations!
Published in 2017 at "Bioresource technology"

DOI: 10.1016/j.biortech.2017.05.048

Abstract: Multi-electrode bioelectrochemical treatment system (ME-BET; membrane less) consisting of six electrode assemblies (E1-E6) was designed and fabricated for the treatment of complex chemical based wastewater with high salt concentration. The performance was compared with single… read more here.

Keywords: multi; system; treatment; electrode bioelectrochemical ... See more keywords
Photo from wikipedia

Determination of optimum electrical connection mode for multi-electrode-embedded microbial fuel cells coupled with anaerobic digester for enhancement of swine wastewater treatment efficiency and energy recovery.

Sign Up to like & get
recommendations!
Published in 2019 at "Bioresource technology"

DOI: 10.1016/j.biortech.2019.122464

Abstract: In this work, three multi-electrode-embedded microbial fuel cells (MFCs) were connected sequentially and operated in series and parallel modes, fed by effluent of an anaerobic digester continuously operated using swine wastewater. The anaerobic digester achieved… read more here.

Keywords: mode; anaerobic digester; electrode embedded; multi electrode ... See more keywords
Photo by julee_juu from unsplash

Simultaneous multisite detection of quantal release from PC12 cells using micro graphitic-diamond multi electrode arrays.

Sign Up to like & get
recommendations!
Published in 2019 at "Biophysical chemistry"

DOI: 10.1016/j.bpc.2019.106241

Abstract: Micro graphitic - diamond - multi electrode arrays (μG-D-MEAs) are suitable for measuring multisite quantal dopamine (DA) release from PC12 cells. Following cell stimulation with high extracellular KCl and electrode polarization at +650 mV, amperometric spikes… read more here.

Keywords: graphitic diamond; diamond multi; pc12 cells; micro graphitic ... See more keywords
Photo from wikipedia

Design and validation of a multi-electrode embedded sensor to monitor resistivity profiles over depth in concrete

Sign Up to like & get
recommendations!
Published in 2019 at "Construction and Building Materials"

DOI: 10.1016/j.conbuildmat.2019.06.226

Abstract: Abstract Electrical resistivity is sensitive to various properties of concrete, such as water content. Usually used on the surface of old structures, devices for measuring such properties could also be adapted in order to be… read more here.

Keywords: multi electrode; resistivity; resistivity profiles; sensor ... See more keywords
Photo from wikipedia

A novel multi-electrode sensing strategy for electrical capacitance tomography with ultra-low dynamic range

Sign Up to like & get
recommendations!
Published in 2017 at "Flow Measurement and Instrumentation"

DOI: 10.1016/j.flowmeasinst.2016.05.005

Abstract: Abstract Common sensing strategy of Electrical Capacitance Tomography (ECT) is to measure the capacitances across all independent combinations of individual electrodes. The capacitance values from conventional sensing strategies usually have large dynamic ranges and severe… read more here.

Keywords: sensing strategy; multi electrode; dynamic range; strategy ... See more keywords
Photo from wikipedia

Pulmonary vein isolation using multi-electrode radiofrequency vs conventional point-by-point radiofrequency ablation: A meta-analysis of randomized and non-randomized studies

Sign Up to like & get
recommendations!
Published in 2017 at "Indian Pacing and Electrophysiology Journal"

DOI: 10.1016/j.ipej.2017.02.004

Abstract: Aims Pulmonary vein isolation is effective in reducing atrial fibrillation (AF) episodes. Previous studies suggest single-shot techniques are effective and safe for this purpose. Procedural and clinical outcomes were compared between multi-electrode and point-by-point radiofrequency… read more here.

Keywords: ablation; point point; radiofrequency; point ... See more keywords
Photo from wikipedia

Sinus node modification utilising a novel multi electrode catheter with orthogonal wavefront mapping

Sign Up to like & get
recommendations!
Published in 2018 at "Indian Pacing and Electrophysiology Journal"

DOI: 10.1016/j.ipej.2018.07.005

Abstract: An 18-year-old female with Ehlers Danlos syndrome and severely intrusive symptoms related to inappropriate sinus tachycardia (IST) despite multiple medications had previously undergone 2 sinus node modifications with limited success. The first procedure used cryo-ablation… read more here.

Keywords: catheter; ablation; sinus node; geometry ... See more keywords
Photo by lucabravo from unsplash

Exploration of a micro multi-electrode technology applied in an air arc heater

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of Physics D: Applied Physics"

DOI: 10.1088/1361-6463/ac0707

Abstract: Arc heaters are vital equipment for the ground thermal appraisal of space probes reentering Earth’s atmosphere. However, the cathodes of arc heaters are currently made of pure copper, and cathode erosion limits the appraisal. A… read more here.

Keywords: electrode technology; micro multi; multi electrode;
Photo from wikipedia

A feasibility study of multi-electrode high-purity germanium detector for 76Ge neutrinoless double beta decay searching

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Instrumentation"

DOI: 10.1088/1748-0221/18/05/p05025

Abstract: Experiments to search for neutrinoless double-beta (0νββ) decay of 76Ge using a high-purity germanium (HPGe) detector rely heavily on background suppression technologies to enhance their sensitivities. In this work, we proposed a pulse-shape analysis method… read more here.

Keywords: network; neutrinoless double; electron; detector ... See more keywords
Photo by sincerelymedia from unsplash

A CMOS Multi-Electrode Array for Four-Electrode Bioimpedance Measurements

Sign Up to like & get
recommendations!
Published in 2022 at "IEEE Transactions on Biomedical Circuits and Systems"

DOI: 10.1109/tbcas.2022.3214243

Abstract: This work demonstrates how a multi-electrode array (MEA) dedicated to four-electrode bioimpedance measurements can be implemented on a complementary metal–oxide–semiconductor (CMOS) chip. As a proof of concept, an 8 × 8 pixel array along with… read more here.

Keywords: electrode; four electrode; electrode bioimpedance; electrode array ... See more keywords