Articles with "non faradaic" as a keyword



Photo from archive.org

3D nanoporous hybrid nanoflower for enhanced non-faradaic redox-free electrochemical impedimetric biodetermination

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of The Taiwan Institute of Chemical Engineers"

DOI: 10.1016/j.jtice.2020.11.006

Abstract: Abstract Recently, non-faradaic electrochemical impedimetric (nfEIS) has been identified as a dynamic and robust method for bio-determining. However, the success of a nfEIS approach largely depends on its sensing layer architecture. In this study, the… read more here.

Keywords: dna; hybrid nanoflower; electrochemical impedimetric; non faradaic ... See more keywords

Effect of Applied AC Voltage on the Performance of Non-Faradaic Impedimetric Biosensors

Sign Up to like & get
recommendations!
Published in 2024 at "Journal of The Electrochemical Society"

DOI: 10.1149/1945-7111/ad2d8c

Abstract: Electrochemical impedance spectroscopy based non-faradaic biosensors are promising low-cost and rapid detection tools for a variety of biomarkers. Unlike faradaic impedimetric biosensors, non-faradaic impedimetric biosensors are redox-free and do not require the use of three… read more here.

Keywords: effect; faradaic impedimetric; voltage; impedimetric biosensors ... See more keywords

Non-Faradaic Impedimetric Detection of Heavy Metal Ions via a Hybrid Nanoparticle-DNAzyme Biosensor

Sign Up to like & get
recommendations!
Published in 2024 at "Biosensors"

DOI: 10.3390/bios14070321

Abstract: Due to rapid industrialization, novel water-quality monitoring techniques for the detection of highly toxic and hazardous heavy metal ions are essential. Herein, a hybrid noble nanoparticle/DNAzyme electrochemical biosensor is proposed for the simultaneous and label-free… read more here.

Keywords: detection; spectroscopy; metal ions; heavy metal ... See more keywords

Evaluation of Non-Faradaic Impedimetric Parameters for IL-8 Detection Using Gold Interdigitated Electrode-Based Biosensors: Towards Early Detection of Newborn Disability

Sign Up to like & get
recommendations!
Published in 2025 at "Micromachines"

DOI: 10.3390/mi16040395

Abstract: Interleukin-8 (IL-8) is a critical biomarker associated with inflammation and disability in both adults and newborns. Conventional detection methods are often labor-intensive, time-consuming, and require highly trained personnel. Non-Faradaic impedimetric biosensors offer a label-free, rapid,… read more here.

Keywords: detection; impedimetric parameters; faradaic impedimetric; sensitivity ... See more keywords