Articles with "nuclear track" as a keyword



Photo by dhika88 from unsplash

Characterization of fluorescent nuclear track detectors as criticality dosimeters

Sign Up to like & get
recommendations!
Published in 2017 at "Radiation Measurements"

DOI: 10.1016/j.radmeas.2017.03.036

Abstract: Abstract Fluorescent nuclear track detectors (FNTDs) are suggested for criticality dosimetry of neutrons and photons. The depth profiles of the fluorescent signal from FNTDs after exposure to high doses of broad spectrum neutron fields from… read more here.

Keywords: nuclear track; neutron; track detectors; criticality ... See more keywords
Photo from archive.org

Fluorescent nuclear track detectors – Review of past, present and future of the technology

Sign Up to like & get
recommendations!
Published in 2018 at "Radiation Measurements"

DOI: 10.1016/j.radmeas.2018.07.005

Abstract: Abstract Fluorescent Nuclear Track Detector technology is a passive luminescent integrating detector technology having important advantages in measuring neutrons, heavy ions and even photons. FNTD is based on new aluminum oxide crystals doped with carbon… read more here.

Keywords: nuclear track; track detectors; technology; detectors review ... See more keywords
Photo from wikipedia

Comparison of charge response of PET films of different brands used as high threshold Nuclear Track Detectors

Sign Up to like & get
recommendations!
Published in 2018 at "Radiation Measurements"

DOI: 10.1016/j.radmeas.2018.10.013

Abstract: Abstract Commercially available polymer films of a particular brand (Desmat CT100), identified as Polyethylene Terephthalate (PET), was shown to be very effective as Nuclear Track Detectors (NTDs) with a very high detection threshold (Z/ β… read more here.

Keywords: nuclear track; charge response; track detectors; films different ... See more keywords
Photo from wikipedia

Convolution based hybrid image processing technique for microscopic images of etch-pits in Nuclear Track Detectors

Sign Up to like & get
recommendations!
Published in 2020 at "Radiation Measurements"

DOI: 10.1016/j.radmeas.2019.106219

Abstract: A novel image processing technique based on convolution is developed for analyzing the etch-pit images in Nuclear Track Detectors (NTDs). Promising results have been obtained for both identifying and counting the etch-pits in the NTDs.… read more here.

Keywords: nuclear track; etch pits; image processing; processing technique ... See more keywords
Photo from wikipedia

Poly (phosphate-co-carbonate) polymers for solid state nuclear track detection application

Sign Up to like & get
recommendations!
Published in 2019 at "Radiation Physics and Chemistry"

DOI: 10.1016/j.radphyschem.2018.11.027

Abstract: Abstract Polymers of triallyl phosphate (TAP) with allyl diglycol carbonate (ADC), pentaerythritol tetrakis allyl carbonate (PETAC) and N-allyloxycarbonyldiethanolaminebis (allyl carbonate) (NADAC) monomers have been prepared and copolymerized with ADC to get poly (ADC-co-TAP), poly (TAP-co-PETAC)… read more here.

Keywords: track detection; tap; track; state nuclear ... See more keywords
Photo from wikipedia

Response of nuclear track detector CR-39 to low energy muons

Sign Up to like & get
recommendations!
Published in 2021 at "Plasma Physics and Controlled Fusion"

DOI: 10.1088/1361-6587/ac2558

Abstract: The effectiveness of the PolyAllyl Diglycol Carbonate (PADC) etched solid state nuclear track detector (SSNTD), commonly known as CR-39, as a muon detector is assessed. CR-39 is successfully used to detect higher rest mass particles… read more here.

Keywords: nuclear track; track detector; detector; response nuclear ... See more keywords
Photo from wikipedia

Thermal and Fast Neutron Dose Equivalent Distribution Measurement of 15-MV Linear Accelerator using a CR-39 Nuclear Track Detectors.

Sign Up to like & get
recommendations!
Published in 2020 at "Radiation protection dosimetry"

DOI: 10.1093/rpd/ncaa001

Abstract: The main purpose of this study is to measure the contribution of the thermal and fast neutron dose along the central axis of the 15 MV Elekta Precise linac in a tissue equivalent phantom. In… read more here.

Keywords: nuclear track; thermal fast; fast neutron; dose equivalent ... See more keywords
Photo by dhika88 from unsplash

MODIFICATION INDUCED BY PROTON IRRADIATION IN BAYFOL UV1 7-2 NUCLEAR TRACK DETECTOR.

Sign Up to like & get
recommendations!
Published in 2018 at "Radiation protection dosimetry"

DOI: 10.1093/rpd/ncy165

Abstract: Bayfol is a class of polymeric solid state nuclear track detector which has many applications in various radiation detection fields. It is a Makrofol polycarbonate/polyester blend. Samples from Bayfol film have been irradiated with different… read more here.

Keywords: nuclear track; bayfol uv1; irradiation; track detector ... See more keywords