Sign Up to like & get
recommendations!
1
Published in 2022 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.13507
Abstract: Abstract Purpose This retrospective work aims to evaluate the possible impact on intra‐ and inter‐observer variability, contouring time, and contour accuracy of introducing a pelvis computed tomography (CT) auto‐segmentation tool in radiotherapy planning workflow. Methods…
read more here.
Keywords:
observer variability;
segmentation tool;
pelvis;
male pelvis ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Clinical Oral Investigations"
DOI: 10.1007/s00784-017-2332-7
Abstract: ObjectivesThe aim of this study was to validate the reproducibility and observer variability of the Functional Implant Prosthodontic Score (FIPS), while considering the level of dental experience for intra- and inter-examiner analysis.Materials and methodsA total…
read more here.
Keywords:
reproducibility;
implant prosthodontic;
reproducibility observer;
observer variability ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2023 at "Nuclear medicine communications"
DOI: 10.1097/mnm.0000000000001704
Abstract: OBJECTIVE To assess the inter-observer variability between readers in the detection of bone metastases for different modalities [planar bone scintigraphy (BS), single photon emission computed tomography/computed tomography (SPECT/CT), and fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography…
read more here.
Keywords:
observer variability;
bone;
bone metastases;
variability readers ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Echocardiography"
DOI: 10.1111/echo.13712
Abstract: Right ventricular systolic pressure (RVSP) estimated by echocardiography is critical for the initial screening and follow‐up of pulmonary hypertension (PH). Inter‐observer variability (IOV) in RVSP can impact clinical decision making. This study assessed whether a…
read more here.
Keywords:
observer variability;
pulmonary hypertension;
inter observer;
Sign Up to like & get
recommendations!
0
Published in 2019 at "Echocardiography"
DOI: 10.1111/echo.14202
Abstract: Echocardiography is used to quantitatively characterize cardiovascular function in fetuses with cardiac abnormalities and inform decisions for fetal or perinatal interventions. It is clinically important to understand the reproducibility of these measures, particularly between testers.…
read more here.
Keywords:
observer variability;
retest variability;
test retest;
variability ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "Pediatric Dermatology"
DOI: 10.1111/pde.15015
Abstract: Guidelines and expert recommendations on infantile hemangiomas (IH) are aimed at increasing homogeneity in clinical decisions based on the risk of sequelae.
read more here.
Keywords:
observer variability;
inter intra;
intra observer;
infantile hemangiomas ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2025 at "Journal of Medical Imaging"
DOI: 10.1117/1.jmi.12.5.051807
Abstract: Abstract. Purpose Four-dimensional (4D) ultrasound imaging is widely used in clinics for diagnostics and therapy guidance. Accurate target tracking in 4D ultrasound is crucial for autonomous therapy guidance systems, such as radiotherapy, where precise tumor…
read more here.
Keywords:
variability;
inter observer;
intra inter;
landmark ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "Frontiers in Oncology"
DOI: 10.3389/fonc.2022.817413
Abstract: Background and Purpose This study aimed to investigate inter-/intra-observer delineation variability in GTVs of primary esophageal carcinomas (ECs) based on planning CT with reference to different combinations of diagnostic multimodal images from endoscopy/EUS, esophagography and…
read more here.
Keywords:
observer variability;
intra observer;
multimodal images;
diagnostic multimodal ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "Diagnostics"
DOI: 10.3390/diagnostics14020216
Abstract: The NIMO TEMPO (Lambda-X, Nivelles, Belgium) is a novel, user-friendly and compact device designed for in vitro optical analysis of refractive and diffractive intraocular lenses (IOLs). This device analyzes the IOL wavefront and generates a…
read more here.
Keywords:
device;
metrology;
inter observer;
metrology device ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Journal of Postgraduate Medicine"
DOI: 10.4103/0022-3859.201412
Abstract: Purpose: The aim of this study was to assess inter- and intra-observer variability of arm muscle thickness measured by critical care physicians using bedside ultrasonography (USG). Methodology: This prospective study included twenty patients admitted with…
read more here.
Keywords:
muscle;
observer variability;
muscle thickness;
critical care ... See more keywords
Photo from archive.org
Sign Up to like & get
recommendations!
0
Published in 2018 at "Journal of neurogastroenterology and motility"
DOI: 10.5056/jnm24031
Abstract: The figure 6 should have been presented as follows.
read more here.
Keywords:
factors determining;
variability diagnostic;
motility;