Sign Up to like & get
recommendations!
1
Published in 2019 at "Catheterization and Cardiovascular Interventions"
DOI: 10.1002/ccd.28201
Abstract: Prosthesis‐patient mismatch (PPM) in TAVR is relatively common Valve oversizing can potentially prevent both paravalvular leak and PPM PPM may be avoidable if the expected Effective Orifice Area/Body Surface Area ratio is considered in decision…
read more here.
Keywords:
prosthesis patient;
match made;
patient mismatch;
Sign Up to like & get
recommendations!
0
Published in 2019 at "Journal of the American College of Cardiology"
DOI: 10.1016/j.jacc.2019.08.062
Abstract: A significant number of patients (pts) after surgical aortic valve replacement (SAVR) show prosthesis-patient mismatch (PPM), which increases mortality. Bioprosthetic valve fracture (BVF) reduces residual gradients after valve-in-valve transcatheter aortic valve replacement (VIV-TAVR).Our aim was…
read more here.
Keywords:
valve fracture;
valve;
bioprosthetic valve;
patient mismatch ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "Journal of the American College of Cardiology"
DOI: 10.1016/s0735-1097(18)31674-7
Abstract: Impact of transcatheter valve choice on prosthesis-patient mismatch (PPM) remains unknown. We compared moderate and severe PPM among Edwards Sapien (ES), Medtronic CoreValve (MC) and BostonScientific Lotus (BL) in a theoretical model. From 6/2014 to…
read more here.
Keywords:
valve choice;
prosthesis patient;
theoretical model;
patient mismatch ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2020 at "Journal of Cardiac Surgery"
DOI: 10.1111/jocs.15108
Abstract: The hemodynamic effect and early and late survival impact of prosthesis–patient mismatch (PPM) after mitral valve replacement remains insufficiently explored.
read more here.
Keywords:
prosthesis patient;
mitral valve;
patient mismatch;
valve replacement ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2019 at "Journal of Cardiovascular Medicine"
DOI: 10.2459/jcm.0000000000000819
Abstract: AIMS Aortic prosthesis-patient mismatch (PPM) increases left ventricular (LV) afterload and prevents LV mass regression (LVMR) after surgery. This study was designed to investigate the association between the baseline global longitudinal strain (GLS) and the…
read more here.
Keywords:
regression;
gls;
prosthesis patient;
prosthesis ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "Frontiers in Cardiovascular Medicine"
DOI: 10.3389/fcvm.2022.931207
Abstract: Background A severe prosthesis-patient mismatch (PPM) is associated with adverse outcomes following transcatheter aortic valve replacement (TAVR) for de novo aortic stenosis or a failed surgical bioprosthesis. The impact of severe PPM in patients undergoing…
read more here.
Keywords:
severe ppm;
valve;
transcatheter aortic;
ppm ... See more keywords