Articles with "peak" as a keyword



Photo from wikipedia

Sensitivity analysis of Monte Carlo model of a gantry‐mounted passively scattered proton system

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.12803

Abstract: Abstract Purpose This study aimed to present guidance on the correlation between treatment nozzle and proton source parameters, and dose distribution of a passive double scattering compact proton therapy unit, known as Mevion S250. Methods… read more here.

Keywords: physical dose; peak; proton; sensitivity ... See more keywords
Photo by fakurian from unsplash

Maximum Emission Peak Over 1500 nm of Organic Assembly for Blood–Brain Barrier‐Crossing NIR‐IIb Phototheranostics of Orthotopic Glioblastoma

Sign Up to like & get
recommendations!
Published in 2023 at "Advanced Materials"

DOI: 10.1002/adma.202208097

Abstract: The development of blood–brain barrier (BBB)‐crossing phototheranostic agents in second near‐infrared window (NIR‐II), especially in the range of 1500–1700 nm (NIR‐IIb), affords great opportunities for glioblastoma (GBM) management. Herein, an organic assembly (denoted as LET‐12)… read more here.

Keywords: iib phototheranostics; blood brain; peak; nir iib ... See more keywords
Photo by clementproust from unsplash

Cytomegalovirus kinetics after hematopoietic cell transplantation reveal peak titers with differential impact on mortality, relapse and immune reconstitution

Sign Up to like & get
recommendations!
Published in 2021 at "American Journal of Hematology"

DOI: 10.1002/ajh.26094

Abstract: Even in the era of PCR‐based monitoring, prophylaxis, and preemptive therapy, Cytomegalovirus (CMV) viremia remains a relevant cause of non‐relapse mortality (NRM) after allogeneic hematopoietic cell transplantation (HCT). However, studies using binary analysis (presence/absence of… read more here.

Keywords: cmv; reconstitution; relapse; peak ... See more keywords
Photo from wikipedia

Spin polarization through axially chiral linkers: Length dependence and correlation with the dissymmetry factor.

Sign Up to like & get
recommendations!
Published in 2023 at "Chirality"

DOI: 10.1002/chir.23556

Abstract: The chiral-induced spin selectivity (CISS) effect relates to the spin-selective electron transport through chiral molecules; therefore, the chiral molecules act as spin filters. In past studies, correlation was found between the magnitude of the spin… read more here.

Keywords: spin polarization; spin; dissymmetry factor; peak ... See more keywords
Photo by zburival from unsplash

Prognostic impact of peak oxygen uptake and heart rate reserve in patients after off‐pump coronary artery bypass grafting

Sign Up to like & get
recommendations!
Published in 2021 at "Clinical Cardiology"

DOI: 10.1002/clc.23579

Abstract: Peak oxygen uptake (peak VO2) and heart rate reserve (HRR) are independent prognostic markers of cardiovascular disease. However, the impact of peak VO2 and HRR on long‐term prognosis after off‐pump coronary artery bypass grafting (OP‐CABG)… read more here.

Keywords: oxygen uptake; peak oxygen; rate reserve; peak ... See more keywords
Photo by sarahsosiak from unsplash

MRS of pilocytic astrocytoma: The peak at 2 ppm may not be NAA

Sign Up to like & get
recommendations!
Published in 2017 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.26374

Abstract: To determine whether the chemical shift of residual N‐acetylaspartate (NAA) signal in pilocytic astrocytomas (PA) is consistent with the position of the NAA peak in controls. read more here.

Keywords: pilocytic astrocytoma; mrs pilocytic; ppm may; peak ... See more keywords
Photo from wikipedia

High‐resolution peak analysis in TOF SIMS data

Sign Up to like & get
recommendations!
Published in 2020 at "Surface and Interface Analysis"

DOI: 10.1002/sia.6872

Abstract: High mass resolution time‐of‐flight secondary ion mass spectrometry (TOF SIMS) can provide a wealth of chemical information about a sample, but the analysis of such data is complicated by detector dead‐time effects that lead to… read more here.

Keywords: sample; analysis; tof sims; resolution ... See more keywords
Photo by zburival from unsplash

Mineral Transform and Specific Heat Capacity Characterization of Blast Furnace Slag with High Al2O3 in Heating Process

Sign Up to like & get
recommendations!
Published in 2020 at "steel research international"

DOI: 10.1002/srin.202000448

Abstract: The specific heat capacity (Cp) of blast furnace (BF) slag critically impacts BF smelting and reports on the Cp of BF slag with high Al2O3 are rare. Mineral transform and Cp characterization of synthesized BF… read more here.

Keywords: al2o3; cao; peak; slag ... See more keywords
Photo from wikipedia

Sexual dimorphism in heart rate recovery from peak exercise

Sign Up to like & get
recommendations!
Published in 2017 at "European Journal of Applied Physiology"

DOI: 10.1007/s00421-017-3627-8

Abstract: PurposeThere is lack of consensus on whether sex, per se, affects heart rate recovery (HRR). To discriminate between the role of sex and that of cardiovascular fitness on HRR, we compared two groups of male… read more here.

Keywords: peak exercise; recovery; heart rate; peak ... See more keywords
Photo by zburival from unsplash

Influence of sex-specific concurrent changes in age, maturity status, and morphological covariates on the development of peak ventilatory variables in 10–17-year-olds

Sign Up to like & get
recommendations!
Published in 2020 at "European Journal of Applied Physiology"

DOI: 10.1007/s00421-020-04569-1

Abstract: Purposes (i) To investigate the influence of concurrent changes in age, maturity status, stature, body mass, and skinfold thicknesses on the development of peak ventilatory variables in 10–17-year-olds; and, (ii) to evaluate the interpretation of… read more here.

Keywords: usepackage; age; development peak; peak ... See more keywords
Photo from wikipedia

Response to the Commentary on ‘Concordant Validity of a Digital Peak Cough Flow Meter to Assess Voluntary Cough Strength in Individuals with ALS’

Sign Up to like & get
recommendations!
Published in 2020 at "Dysphagia"

DOI: 10.1007/s00455-020-10132-z

Abstract: We are grateful for the opportunity to respond to a letter to the editor regarding our manuscript “Concordant valid‐ ity of a digital peak cough flow meter to assess voluntary cough strength in individuals with… read more here.

Keywords: cough; peak; expiratory flow; voluntary cough ... See more keywords