Articles with "periprosthetic osteolysis" as a keyword



The effect of strontium ranelate on titanium particle-induced periprosthetic osteolysis regulated by WNT/β-catenin signaling in vivo and in vitro

Sign Up to like & get
recommendations!
Published in 2021 at "Bioscience Reports"

DOI: 10.1042/bsr20203003

Abstract: Abstract Aseptic loosening following periprosthetic osteolysis is the primary complication that limits the lifetime of total joint arthroplasty (TJA). The wear particles trigger a chronic inflammation response in the periprosthetic tissue and turn over the… read more here.

Keywords: periprosthetic osteolysis; strontium ranelate; ranelate; particle induced ... See more keywords
Photo from wikipedia

Catastrophic Periprosthetic Osteolysis in Total Hip Arthroplasty at 20 Years: A Case Report and Literature Review

Sign Up to like & get
recommendations!
Published in 2022 at "Orthopaedic Surgery"

DOI: 10.1111/os.13322

Abstract: Periprosthetic osteolysis is a serious complication following total hip arthroplasty (THA). However, most orthopedic surgeons only focus on bone loss and hip reconstruction. Thus, it was required to understand the treatment algorithm for periprosthetic osteolysis… read more here.

Keywords: osteolysis; total hip; catastrophic periprosthetic; periprosthetic osteolysis ... See more keywords
Photo by tolga__ from unsplash

Cimifugin Suppresses NF-κB Signaling to Prevent Osteoclastogenesis and Periprosthetic Osteolysis

Sign Up to like & get
recommendations!
Published in 2021 at "Frontiers in Pharmacology"

DOI: 10.3389/fphar.2021.724256

Abstract: Background: Aseptic loosening of prosthesis (ALP) is one of the most common long-term complications of knee and hip arthroplasty. Wear particle-induced osteoclastogenesis and subsequent periprosthetic osteolysis account for the morbidity of ALP. Here, we investigate… read more here.

Keywords: periprosthetic osteolysis; cimifugin; cim; bone ... See more keywords

Pyroptosis in Periprosthetic Osteolysis

Sign Up to like & get
recommendations!
Published in 2022 at "Biomolecules"

DOI: 10.3390/biom12121733

Abstract: Periprosthetic osteolysis (PPO) along with aseptic loosening (AL) caused by wear particles after artificial joint replacement is the key factor in surgical failure and subsequent revision surgery, however, the precise molecular mechanism underlying PPO remains… read more here.

Keywords: periprosthetic osteolysis; pyroptosis; ppo; pyroptosis periprosthetic ... See more keywords