Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2019 at "Journal of the Brazilian Society of Mechanical Sciences and Engineering"
DOI: 10.1007/s40430-019-1991-5
Abstract: High pressurisation is one of the important developmental techniques for piston pumps. Given that press-fit cylinder blocks of instruction machinery develop cracks or breakage; based on the DIN 7190(2001) and GB/T 5371-2004, the amounts of…
read more here.
Keywords:
press fit;
cylinder;
piston pumps;
fit cylinder ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2022 at "Arthroplasty Today"
DOI: 10.1016/j.artd.2022.02.012
Abstract: Background Patellar resurfacing is routinely performed during total knee arthroplasty to reduce pain associated with patellofemoral osteoarthritis. With 3-dimensional ingrowth materials readily available, the present study aimed to evaluate if cemented polyethylene (CP) patellar buttons…
read more here.
Keywords:
patellae;
load failure;
failure;
patella ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2019 at "Clinical biomechanics"
DOI: 10.1016/j.clinbiomech.2019.06.017
Abstract: BACKGROUND Total hip arthroplasty complications are associated with mechanical loosening of the acetabular component, which may be attributed to the type of fixation used (press fit, trans-cortical screws, cancellous screws). Therefore, the purpose of this…
read more here.
Keywords:
trans cortical;
fixation;
press fit;
cancellous screws ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2020 at "Journal of Manufacturing Processes"
DOI: 10.1016/j.jmapro.2019.11.014
Abstract: Abstract This survey proposes an innovative solution of using low frequency oscillations among wide variety of available disassembly methods for disassemble press-fit joints. Two different schemes of unidirectional path applying vibration waves to the elements…
read more here.
Keywords:
fit joints;
vibration;
vibration wave;
press fit ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Journal of shoulder and elbow surgery"
DOI: 10.1016/j.jse.2017.02.006
Abstract: BACKGROUND Press-fit humeral fixation in reverse shoulder arthroplasty (RSA) has become increasingly popular; however, radiographic analysis of these stems is limited. We aimed to evaluate the radiographic and clinical outcomes of an adjustable diaphyseal press-fit…
read more here.
Keywords:
diaphyseal press;
clinical outcomes;
adjustable diaphyseal;
press fit ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2018 at "Journal of shoulder and elbow surgery"
DOI: 10.1016/j.jse.2017.11.010
Abstract: BACKGROUND The influence of primary humeral stem fixation method (cemented or press fit) on intraoperative or postoperative outcomes in the setting of revision shoulder arthroplasty is unknown. METHODS A retrospective analysis of a prospectively collected…
read more here.
Keywords:
revision;
fixation;
shoulder;
press fit ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2018 at "Journal of shoulder and elbow surgery"
DOI: 10.1016/j.jse.2017.12.020
Abstract: Uncemented press-fit humeral stems were developed with the goal of decreasing operative time, preserving bone stock, and easing revision. In recent years, short stems and stemless humeral implants have also become available. These press-fit humeral…
read more here.
Keywords:
stress shielding;
press fit;
press;
shoulder arthroplasty ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2020 at "Journal of shoulder and elbow surgery"
DOI: 10.1016/j.jse.2019.09.042
Abstract: BACKGROUND The purpose of this study was to compare the functional outcomes and humeral stress shielding of a reverse shoulder arthroplasty (RSA) placed with either cement or press-fit fixation. The hypothesis was that there would…
read more here.
Keywords:
stress shielding;
press fit;
press;
fixation ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2021 at "Journal of shoulder and elbow surgery"
DOI: 10.1016/j.jse.2021.11.005
Abstract: BACKGROUND The literature is sparse comparing humeral implants in reverse shoulder arthroplasty (RSA). With minimal supporting literature, there has been a trend away from standard length cemented humeral implants to press-fit stems, and recently to…
read more here.
Keywords:
press fit;
two years;
standard length;
shoulder ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2021 at "Microelectronics Reliability"
DOI: 10.1016/j.microrel.2020.114010
Abstract: Abstract As the successor of soldering, the press-fit electrical connection is more and more widely used on account of a number of advantages, such as fast assembly. However, in practice, some contact failures were found.…
read more here.
Keywords:
mechanical behavior;
press fit;
connector;
press ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2019 at "Wear"
DOI: 10.1016/j.wear.2018.12.083
Abstract: Abstract The authors of this paper made an attempt to explain fretting wear development in the wheel – axle connection in model studies simulating actual exploitation conditions. The tests consisted of two stages. In the…
read more here.
Keywords:
fit joint;
wear development;
press fit;
fretting wear ... See more keywords