Sign Up to like & get
recommendations!
0
Published in 2017 at "Lasers in Medical Science"
DOI: 10.1007/s10103-017-2381-9
Abstract: It is important to identify factors that affect primary stability of orthodontic mini-implants because it determines the success of treatment. We assessed mini-implant primary stability (initial mechanical engagement with the bone) placed in pig jaws.…
read more here.
Keywords:
mini;
implant insertion;
mini implant;
primary stability ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2018 at "Clinical Biomechanics"
DOI: 10.1016/j.clinbiomech.2018.09.023
Abstract: Background: Fracture fixation in weak bone is still a clinical challenge. Screw augmentation was shown to successfully increase their primary stability. The currently used calcium phosphate or polymeric bone cements, however, present important drawbacks such…
read more here.
Keywords:
increase primary;
primary stability;
bone screws;
bone ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2021 at "Journal of shoulder and elbow surgery"
DOI: 10.1016/j.jse.2020.12.027
Abstract: BACKGROUND The incidence of periprosthetic fractures of the proximal humerus is gradually increasing, following an increase in reverse shoulder arthroplasties (RSA) in the last years. Locking plate fixation and revision arthroplasty are both valuable treatment…
read more here.
Keywords:
subgroup;
primary stability;
fixation;
locking plate ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2018 at "European journal of orthodontics"
DOI: 10.1093/ejo/cjy059
Abstract: Objective The aim of this study was to assess the potential of improving orthodontic miniscrews' (MSs) primary stability in vivo by evaluating the dispersion capacity of an injectable bone graft substitute (iBGS) through a newly…
read more here.
Keywords:
new zealand;
primary stability;
sydney mini;
study ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2022 at "Medicine"
DOI: 10.1097/md.0000000000028866
Abstract: Abstract Background: In case of injuries to the subaxial cervical spine, especially in osteoporotic bone, the question of the most stable operative technique arises. There are several techniques of screw fixation available regarding dorsal stabilization.…
read more here.
Keywords:
screw fixation;
model;
injury;
translational injury ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "Clinical Implant Dentistry and Related Research"
DOI: 10.1111/cid.12574
Abstract: BACKGROUND Changes in the macrogeometry of dental implants are known to influence primary stability and the osseointegration process. PURPOSE The purpose of the present in vitro study was to evaluate the mechanical behavior of geometric…
read more here.
Keywords:
insertion torque;
insertion;
resonance frequency;
primary stability ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2018 at "Clinical Implant Dentistry and Related Research"
DOI: 10.1111/cid.12579
Abstract: BACKGROUND AND PURPOSE Implant stability is one of the most important factors influencing osseointegration. Using stereolithographical guides for maximizing precision, this study aimed at investigating the relationship between implant stability and bone density derived from…
read more here.
Keywords:
stability;
bone density;
implant stability;
primary stability ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2019 at "Clinical oral implants research"
DOI: 10.1111/clr.13491
Abstract: OBJECTIVES There is a need of more studies on whether low primary implant stability would negatively influence the success of implant therapy. Therefore, this retrospective study analyses outcomes of implants placed with low primary stability…
read more here.
Keywords:
primary stability;
implant loss;
low primary;
stability ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
2
Published in 2023 at "Clinical oral implants research"
DOI: 10.1111/clr.14037
Abstract: OBJECTIVES To evaluate the associations between the cortical bone-to-implant contact (CBIC), bone microstructure derived from cone-beam computed tomography (CBCT), and the primary stability of the implant. MATERIALS AND METHODS Twenty-two patients with 65 implants were…
read more here.
Keywords:
primary stability;
associations cortical;
bone;
implant primary ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2022 at "Advances in Mechanical Engineering"
DOI: 10.1177/16878132221081579
Abstract: Though miniscrews are widely used as a temporary anchorage device, research focusing on the primary stability of miniscrew loading torque force is limited. This study is aimed to design a novel torque-resistant miniscrew used as…
read more here.
Keywords:
primary stability;
tro screws;
com screws;
anchorage ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2020 at "Materials"
DOI: 10.3390/ma13071783
Abstract: Adequate primary stability of the acetabular revision construct is necessary for long-term implant survival. The difference in primary stability between tantalum and titanium components is unclear. Six composite hemipelvises with an acetabular defect were implanted…
read more here.
Keywords:
relative motion;
cup;
titanium;
primary stability ... See more keywords