Articles with "pullout strength" as a keyword



Photo by flysi3000 from unsplash

Effect of Anchor Length on the Pullout Strength of Palatal Mini Implants

Sign Up to like & get
recommendations!
Published in 2017 at "Implant Dentistry"

DOI: 10.1097/id.0000000000000579

Abstract: Purpose: The aim of this study was to evaluate the pullout strength of 3 different orthodontic mini implants. Materials and Methods: Twenty-seven mini implants (diameter: 2 mm, length: 7 mm) were implanted into artificial bone… read more here.

Keywords: pullout strength; mini implants; anchor length;
Photo by majesticlukas from unsplash

Evaluation of the Relation Between Preload Values and Pullout Force of the Cortical Screw Used in Bone Fracture.

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of biomechanical engineering"

DOI: 10.1115/1.4051186

Abstract: This study aims to examine the relation between pullout strength and preload values of the cortical screw used in bone fracture fixation. The research question is that "Does the pullout strength of the cortical screw… read more here.

Keywords: cortical screw; pullout strength; bone; preload values ... See more keywords
Photo from wikipedia

A Novel Screw Modeling Approach to Study the Effects of Screw Parameters on Pullout Strength.

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of biomechanical engineering"

DOI: 10.1115/1.4055035

Abstract: Screw loosening remains a prominent problem for osteoporotic patients undergoing pedicle screw fixation surgeries and is affected by screw parameters (e.g., diameter, pitch and thread angle). However, the individual and interactive effects of these parameters… read more here.

Keywords: screw approach; screw parameters; pullout strength; approach ... See more keywords
Photo from wikipedia

Biomechanical comparison of pedicle screw fixation strength among three different screw trajectories using single vertebrae and one-level functional spinal unit

Sign Up to like & get
recommendations!
Published in 2022 at "Frontiers in Bioengineering and Biotechnology"

DOI: 10.3389/fbioe.2022.1054738

Abstract: Three key factors are responsible for the biomechanical performance of pedicle screw fixation: screw mechanical characteristics, bone quality and insertion techniques. To the best of the authors’ knowledge, no study has directly compared the biomechanical… read more here.

Keywords: strength; among three; single vertebrae; pullout strength ... See more keywords
Photo by majesticlukas from unsplash

Pullout Strength of Pedicle Screws Inserted Using Three Different Techniques: A Biomechanical Study on Polyurethane Foam Block

Sign Up to like & get
recommendations!
Published in 2023 at "Bioengineering"

DOI: 10.3390/bioengineering10060660

Abstract: Pullout strength is an important indicator of the performance and longevity of pedicle screws and can be heavily influenced by the screw design, the insertion technique and the quality of surrounding bone. The purpose of… read more here.

Keywords: strength; inserted using; pedicle; insertion ... See more keywords
Photo by nuvaproductions from unsplash

Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction Volume

Sign Up to like & get
recommendations!
Published in 2021 at "Materials"

DOI: 10.3390/ma14205991

Abstract: The microthread neck concept has been applied to dental implants. This study investigated the pullout strength and destruction volume of orthodontic microimplants with and without the microthread neck design. Fifteen microimplants (diameter: 1.5 Ă— 10… read more here.

Keywords: neck; pullout strength; destruction volume; microimplant neck ... See more keywords