Articles with "readout" as a keyword



Photo from wikipedia

Arterial spin labeling using spatio‐temporal encoding readout for robust perfusion imaging in inhomogenous magnetic fields

Sign Up to like & get
recommendations!
Published in 2022 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.29506

Abstract: To evaluate the feasibility of spatio‐temporal encoding (SPEN) readout for pseudo‐continuous ASL (pCASL) in brain, and its robustness to susceptibility artifacts as introduced by aneurysm clips. read more here.

Keywords: temporal encoding; arterial spin; spin labeling; readout ... See more keywords
Photo from wikipedia

Multi‐readout DWI with a reduced FOV for studying the coupling between diffusion and T2* relaxation in the prostate

Sign Up to like & get
recommendations!
Published in 2023 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.29636

Abstract: To develop a DWI sequence with multiple readout echo‐trains in a single shot (multi‐readout DWI) over a reduced FOV, and to demonstrate its ability to achieve high data acquisition efficiency in the study of coupling… read more here.

Keywords: coupling diffusion; multi readout; dwi reduced; readout dwi ... See more keywords
Photo by clemono from unsplash

Design and validation of the readout circuitry for an in-cell active-matrix capacitive (IAMC) touch panel

Sign Up to like & get
recommendations!
Published in 2018 at "Microsystem Technologies"

DOI: 10.1007/s00542-018-3948-5

Abstract: This study is dedicated to design an in-cell active-matrix capacitive (IAMC) touch panel and its readout circuitry. This IAMC touch panel is in a structure that embeds all components for touch panel in a standard… read more here.

Keywords: active matrix; touch panel; iamc touch; panel ... See more keywords
Photo by jordanmcdonald from unsplash

On-Sky Performance of the SPT-3G Frequency-Domain Multiplexed Readout

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Low Temperature Physics"

DOI: 10.1007/s10909-019-02280-w

Abstract: Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition-edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a… read more here.

Keywords: frequency domain; performance spt; spt; readout ... See more keywords
Photo by like_that_mike from unsplash

Superconductor-Ferromagnet Tunnel Junction Thermoelectric Bolometer and Calorimeter with a SQUID Readout

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Low Temperature Physics"

DOI: 10.1007/s10909-020-02419-0

Abstract: The superconductor-ferromagnet thermoelectric detector (SFTED) is a novel ultrasensitive radiation detector based on the giant thermoelectric effect in superconductor-ferromagnet tunnel junctions. This type of detector can be operated without the need of additional bias lines… read more here.

Keywords: ferromagnet tunnel; squid readout; readout; superconductor ferromagnet ... See more keywords
Photo from wikipedia

Design of readout electronics based on peak-holding circuit and multiplexer for a fast neutron spectrometer

Sign Up to like & get
recommendations!
Published in 2018 at "Radiation Detection Technology and Methods"

DOI: 10.1007/s41605-017-0033-z

Abstract: BackgroundFast neutron detection is meaningful in many research fields such as space environment monitoring. A scintillating fiber array model for fast neutron detection was proposed and developed in 1980s. Aerospace applications of the model require… read more here.

Keywords: peak holding; system; fast neutron; neutron detection ... See more keywords
Photo from wikipedia

Target-triggered aggregation of gold nanoparticles for photothermal quantitative detection of adenosine using a thermometer as readout.

Sign Up to like & get
recommendations!
Published in 2020 at "Analytica chimica acta"

DOI: 10.1016/j.aca.2020.03.023

Abstract: Colorimetric platform using the aggregation of gold nanoparticles (AuNPs) is a pretty simple method for biosensing, but advanced instruments such as specterophotometer is still needed to achieve accurately quantitative readout. Aggregated AuNPs exhibit excellent photothermal… read more here.

Keywords: aggregation; detection; gold nanoparticles; aggregation gold ... See more keywords
Photo by roanlavery from unsplash

Fluorimetric readout of ion-selective electrode potential changes

Sign Up to like & get
recommendations!
Published in 2018 at "Electrochimica Acta"

DOI: 10.1016/j.electacta.2018.07.130

Abstract: Abstract A novel method of quantitative optical readout of potentiometric responses of ion-selective electrodes is proposed. This idea was realized in a simple self-powered bipolar electrode system, with an ion-selective pole directly connected with the… read more here.

Keywords: ion selective; selective electrode; system; readout ... See more keywords
Photo from wikipedia

Development of 2D GEM-based SXR plasma imaging for DTT device: Focus on readout structure

Sign Up to like & get
recommendations!
Published in 2021 at "Fusion Engineering and Design"

DOI: 10.1016/j.fusengdes.2021.112443

Abstract: Abstract Creation and development of a new diagnostics useful for future thermonuclear reactors and helpful in studying impurity profiles, MHD modes/localization, and imaging are among urgent tasks in plasma research field. Global SXR imaging for… read more here.

Keywords: development; plasma; structure; gem based ... See more keywords
Photo from wikipedia

Thermal-optical readout of multi-level thermal emissivity Ge2Sb2Te5 patterns

Sign Up to like & get
recommendations!
Published in 2019 at "Materials Letters"

DOI: 10.1016/j.matlet.2019.126728

Abstract: Abstract Ge2Sb2Te5 thin film (100 nm) can be patterned with multi-level crystalline and thermal emissivity states using laser in large scale. Various patterns can be fabricated by tuning laser power and speed. X-ray diffraction (XRD) and… read more here.

Keywords: ge2sb2te5 thin; thermal emissivity; multi level; emissivity ... See more keywords
Photo from wikipedia

Combination of integrated dynamic shimming and readout-segmented echo planar imaging for diffusion weighted MRI of the head and neck region at 3Tesla.

Sign Up to like & get
recommendations!
Published in 2017 at "Magnetic resonance imaging"

DOI: 10.1016/j.mri.2017.05.004

Abstract: PURPOSE To evaluate the performance of combined integrated slice-by-slice shimming and readout-segmented EPI (irsEPI) for diffusion-weighted MR imaging (DWI) of the neck at 3Tesla. METHODS This study was approved by the local ethics committee. An… read more here.

Keywords: readout; diffusion; readout segmented; head neck ... See more keywords