Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2017 at "Steel Research International"
DOI: 10.1002/srin.201600286
Abstract: The reinforcing bars provide necessary structural support for the buildings made with concrete under normal and demanding conditions. The two most structurally demanding situations in building can arise under seismic activities and fire. This paper…
read more here.
Keywords:
thermo mechanically;
rebar;
mechanically treated;
impact ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2020 at "Automation in Construction"
DOI: 10.1016/j.autcon.2020.103172
Abstract: Abstract Reinforced concrete (RC) beam-column joints are the critical components of RC building frames. Congestion and even collision of reinforcing bars (rebars) encounter frequently in the core region of a joint. The building information modeling…
read more here.
Keywords:
building frames;
rebar;
potential field;
collision ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2021 at "Automation in Construction"
DOI: 10.1016/j.autcon.2021.103974
Abstract: Abstract This study investigated frequency-difference electrical resistance tomography (ERT) using a 16-channel ERT system to detect rebar embedded in cement mortar. Two different data collecting methods (i.e., reference-difference and frequency-difference) were used for ERT image…
read more here.
Keywords:
rebar;
difference;
frequency difference;
cement mortar ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2018 at "Construction and Building Materials"
DOI: 10.1016/j.conbuildmat.2018.05.128
Abstract: Abstract The purpose of this study is to investigate the temperature effects on the bond strength between concrete and steel reinforcement bars. For two different steel bars (epoxy-coated and uncoated bars), three experimental parameters (heating…
read more here.
Keywords:
rebar;
bond;
strength concrete;
steel ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2019 at "Construction and Building Materials"
DOI: 10.1016/j.conbuildmat.2018.12.070
Abstract: Abstract The shear behavior of stubby Y-type perfobond rib shear connectors differs according to the diameter of the transverse rebar used for composite action. Pull-push test specimens with transverse rebar of different diameters (D10, D13,…
read more here.
Keywords:
transverse rebar;
rebar;
rib shear;
type perfobond ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2020 at "Construction and Building Materials"
DOI: 10.1016/j.conbuildmat.2019.117615
Abstract: Abstract Rebar corrosion can lead to significant deterioration in bond strength between steel and concrete. However, since confinement is lost as the concrete cracks, the changes in frictional bonding and mechanical bonding resulting from corrosion…
read more here.
Keywords:
rebar;
bond;
model;
corrosion ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2020 at "Construction and Building Materials"
DOI: 10.1016/j.conbuildmat.2020.121646
Abstract: Abstract The calculation model of segment rebar corrosion is formulated to study the rebar corrosion induced by stray direct current in the cracked segment of a shield tunnel. The model includes the upper track bed…
read more here.
Keywords:
rebar;
stray current;
segment;
rebar corrosion ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2021 at "Construction and Building Materials"
DOI: 10.1016/j.conbuildmat.2020.121716
Abstract: Abstract This research presents the investigation of the effect of anti-corrosive coatings on the bond behavior of corroded rebar to concrete. Cementitious and epoxy types of anti-corrosive coating materials have been considered and applied manually…
read more here.
Keywords:
bond behavior;
anti corrosive;
rebar;
effect ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2021 at "Construction and Building Materials"
DOI: 10.1016/j.conbuildmat.2021.122313
Abstract: Abstract We evaluated rebar corrosions in a continuously reinforced concrete pavement (CRCP) in use for more than 30 years through field surveys. Ultrasonic shear-wave tomography analysis and concrete coring indicated that horizontal cracks occurred within approximately…
read more here.
Keywords:
rebar;
continuously reinforced;
rebar corrosion;
transverse cracks ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2020 at "Case Studies in Thermal Engineering"
DOI: 10.1016/j.csite.2020.100812
Abstract: Abstract Understanding the concrete-steel interface's behavior at cryogenic temperatures is important for designing concrete for direct liquefied natural gas (LNG) containment; such behavior is currently unclear. Hence, the work conducted involved pull-out testing in providing…
read more here.
Keywords:
lng containment;
rebar;
bond;
bond slip ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2021 at "Engineering Failure Analysis"
DOI: 10.1016/j.engfailanal.2021.105720
Abstract: Abstract Carbon steel rebar seriously corrodes in severe tropical marine atmospheric environment, threatening the safety of building structures. Hence, it is of great significance to design and manufacture low-alloy steel rebar which can be used…
read more here.
Keywords:
rebar;
alloy;
steel rebar;
tropical marine ... See more keywords