Published in 2017 at "Chemical Engineering Journal"
DOI: 10.1016/j.cej.2016.09.041
Abstract: Abstract The maximum temperature of a synthesis reaction (MTSR) is an important criterion for process risk assessment and reactor design. In this paper, the variation of the dimensionless MTSR 0 and θ MTSR (the instant…
read more here.
Keywords:
new criterion;
mtsr;
safe operating;
criterion identify ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "Environmental Science & Technology"
DOI: 10.1021/acs.est.2c00524
Abstract: P et al. argue that we are outside the safe operating space of the planetary boundary for novel entities, since the annual production and releases of chemicals including plastics are increasing at a pace that…
read more here.
Keywords:
operating space;
planetary boundary;
safe operating;
novel entities ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2019 at "IEEE Transactions on Electron Devices"
DOI: 10.1109/ted.2019.2942372
Abstract: In this article, we have proposed a simple, novel, and cost-effective technique to mitigate the ON-state performance issues in laterally diffused MOS (LDMOS) transistors. We propose a novel technique-LDMOS transistor with source-side underlap (SU), which…
read more here.
Keywords:
area;
novel technique;
safe operating;
ldmos transistors ... See more keywords
Sign Up to like & get
recommendations!
4
Published in 2023 at "IEEE Transactions on Electron Devices"
DOI: 10.1109/ted.2023.3264529
Abstract: In this article, the “segmented gate (SG)” concept is proposed and implemented in trench gate to realize both low loss and wide safe-operating area (SOA) for insulated-gate bipolar transistors (IGBTs). The poly gate of the…
read more here.
Keywords:
segmented gate;
loss;
gate concept;
operating area ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2021 at "IEEE Transactions on Power Electronics"
DOI: 10.1109/tpel.2021.3072205
Abstract: This letter proposes a safe operating area (SOA) concept for film capacitors in dc-link applications. The SOA is presented by capacitor voltage and ripple current, considering the impact of ambient temperature, degradation, and parameter variance.…
read more here.
Keywords:
operating area;
area link;
safe operating;
film capacitors ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2021 at "Robotics"
DOI: 10.3390/robotics10030097
Abstract: A drive to reduce costs, carbon emissions, and the number of required personnel in the offshore energy industry has led to proposals for the increased use of autonomous/robotic systems for many maintenance tasks. There are…