Articles with "scan body" as a keyword



Photo from wikipedia

Influence of the implant scan body geometry bevel feature position, implant angulation, and position on intraoral scanning accuracy: An in vitro study.

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of dentistry"

DOI: 10.1016/j.jdent.2022.104122

Abstract: PURPOSE To assess the influence of the scan body geometry bevel position and implant angulation and position of complete-arch implant digital scans. MATERIAL AND METHODS Two definitive casts with 4 implant analogs placed parallel (P… read more here.

Keywords: body geometry; scan body; geometry; geometry bevel ... See more keywords
Photo from wikipedia

The effect of scanning the palate and scan body position on the accuracy of complete-arch implant scans.

Sign Up to like & get
recommendations!
Published in 2019 at "Clinical implant dentistry and related research"

DOI: 10.1111/cid.12821

Abstract: BACKGROUND Whether stitching the palate during intraoral digital scans of implants would improve, scanning accuracy is unclear. PURPOSE Evaluate the effect of stitching the palate and the scan body position on the trueness (distance and… read more here.

Keywords: position; effect; body position; scan body ... See more keywords
Photo by markusspiske from unsplash

Does the geometry of scan bodies affect the alignment accuracy of computer-aided design in implant digital workflow: an in vitro study?

Sign Up to like & get
recommendations!
Published in 2021 at "Clinical oral implants research"

DOI: 10.1111/clr.13890

Abstract: OBJECTIVES To compare 2 implant scan bodies with different geometry on the accuracy of the virtual alignment process in the digital workflow. MATERIALS AND METHODS A master model of the edentulous maxilla with 6 implants… read more here.

Keywords: scan bodies; digital workflow; geometry; scan body ... See more keywords
Photo from wikipedia

Superimposition of intraoral scans of an edentulous arch with implants and implant-supported provisional restoration, implementing a novel implant prosthetic scan body.

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of prosthodontic research"

DOI: 10.2186/jpr.jpr_d_21_00328

Abstract: PURPOSE To describe a technique utilizing a novel prosthetic scan body, that assists the accurate merging of multiple scans (intra- and extraoral) of the interim prosthesis and edentulous arch with dental implants, during rehabilitation with… read more here.

Keywords: scan body; edentulous arch; prosthesis; prosthetic scan ... See more keywords
Photo from wikipedia

How the geometry of the scan body affects the accuracy of digital impressions in implant supported prosthesis. In vitro study

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Clinical and Experimental Dentistry"

DOI: 10.4317/jced.59948

Abstract: Background To determine and compare how three-dimensionally accurate scan bodies of different geometric shapes are placed over 6 implants (platform or crestal module). Material and Methods A master plaster model was made with 6 INHEX… read more here.

Keywords: scan body; geometry; scan bodies; geometry scan ... See more keywords