Abstract: PURPOSE The determination of X-ray spectra near the maze entrance of linear accelerator (LINAC) rooms is challenging due to the pulsed nature of the LINAC source. Mathematical methods to account for pulse pile-up have been…
read more here.
Keywords:
maze entrance;
monte carlo;
spectrum;
scintillation detectors ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "Medical physics"
DOI: 10.1002/mp.15469
Abstract: PURPOSE Scintillation detectors were 3D printed based on a gamma knife (GK) dose distribution to calculate the volume averaging effect. The collimator output factors were measured using isodose-shaped scintillators (ISSs) and compared with those of…
read more here.
Keywords:
scintillation detectors;
output;
detector;
output factors ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2019 at "Atomic Energy"
DOI: 10.1007/s10512-019-00583-5
Abstract: The purpose of this work is to analyze the use of detecting materials in radiation monitors as well as the replacement of widely used 3H-based neutron counters by neutron-detection scintillation technology. The replacement of helium…
read more here.
Keywords:
helium counters;
detection;
scintillation detectors;
radiation monitors ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2018 at "Physica Medica"
DOI: 10.1016/j.ejmp.2018.04.324
Abstract: Purpose Spatial resolution (SR) and counting efficiency (CE) are two pivotal parameters for Nuclear Medicine devices based on scintillation crystals. These parameters are in conflict with one another: the smaller the thickness of the scintillation…
read more here.
Keywords:
layer;
detector;
phoswich approach;
approach ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2019 at "Physics in medicine and biology"
DOI: 10.1088/1361-6560/ab038b
Abstract: In positron emission tomography (PET), long crystals ([Formula: see text]20 mm) are used to enhance detection efficiency and increase scanner sensitivity. However, for fast time-of-flight (TOF) scanners, this may affect the achievable coincidence time resolution (CTR)…
read more here.
Keywords:
ctr;
time;
model;
scintillation detectors ... See more keywords
Sign Up to like & get
recommendations!
2
Published in 2022 at "Journal of Instrumentation"
DOI: 10.1088/1748-0221/17/01/c01033
Abstract: Scintillation detectors are widely used for hard X-ray spectroscopy and allow us to investigate the dynamics of runaway electrons in tokamaks. This diagnostic tool proved to be able to provide information about the energy or…
read more here.
Keywords:
progress;
scintillation detectors;
compass;
compass tokamaks ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "IEEE Transactions on Nuclear Science"
DOI: 10.1109/tns.2017.2654512
Abstract: Scintillation detectors offer a single-step detection method for fast neutrons and necessitate real-time acquisition, whereas this is redundant in two-stage thermal detection systems using helium-3 and lithium-6, where the fast neutrons need to be thermalized…
read more here.
Keywords:
detector;
scintillation detectors;
acquisition;