Articles with "self shielding" as a keyword



Photo from wikipedia

Absorbed dose kernel and self‐shielding calculations for a novel radiopaque glass microsphere for transarterial radioembolization

Sign Up to like & get
recommendations!
Published in 2018 at "Medical Physics"

DOI: 10.1002/mp.12717

Abstract: PURPOSE Radiopaque microspheres may provide intraprocedural and postprocedural feedback during transarterial radioembolization (TARE). Furthermore, the potential to use higher resolution x-ray imaging techniques as opposed to nuclear medicine imaging suggests that significant improvements in the… read more here.

Keywords: glass; transarterial radioembolization; time; self shielding ... See more keywords
Photo by johnnymcclung from unsplash

Calculation of resonance self-shielding factors in a round disk using the enlarged Doppler Broadening Function

Sign Up to like & get
recommendations!
Published in 2017 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2017.05.051

Abstract: Abstract The activation technique allows much more precise measurements of neutron intensity, relative or absolute. This technique requires the knowledge of the Doppler Broadening Function to determine the resonance self-shielding factors in the epithermal range.… read more here.

Keywords: doppler broadening; broadening function; self shielding; shielding factors ... See more keywords
Photo by molly7 from unsplash

Pin-resolved resonance self-shielding methods in LWR direct transport calculations

Sign Up to like & get
recommendations!
Published in 2017 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2017.08.050

Abstract: Abstract An essential component of deterministic reactor core analysis is the resonance self-shielding calculation, which is used to produce problem-specific multigroup cross sections. Equivalence theory and the subgroup method have been widely used to perform… read more here.

Keywords: resonance; self shielding; self; direct transport ... See more keywords
Photo from wikipedia

Resonance self-shielding treatment and analysis of resonance integral tables for Fully Ceramic Micro-encapsulated fuels with the Embedded Self-Shielding Method

Sign Up to like & get
recommendations!
Published in 2018 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2017.10.027

Abstract: Abstract A resonance calculation method for Fully Ceramic Micro-encapsulated (FCM) fuels containing stochastically dispersed tri-structural isotropic (TRISO) coated fuel particles has been proposed in this research. The purpose is to obtain effective homogenized resonance cross… read more here.

Keywords: fully ceramic; resonance; ceramic micro; method ... See more keywords
Photo from wikipedia

Application of Tone’s and embedded self-shielding methods to pressurized water reactor assemblies

Sign Up to like & get
recommendations!
Published in 2018 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2017.10.031

Abstract: Abstract The Tone’s and embedded self shielding methods are based on a heterogeneous-homogeneous equivalence principle. They both provide a formula for an equivalent dilution parameter that can be used to interpolate pretabulated effective cross sections… read more here.

Keywords: embedded self; shielding methods; tone embedded; self shielding ... See more keywords
Photo from wikipedia

Estimation of resonance self-shielding effect in PWR pin cell for different fuel types

Sign Up to like & get
recommendations!
Published in 2018 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2018.06.045

Abstract: Abstract The most important factors in any code used for nuclear reactor modeling are the time and precision of the results. In principle, deterministic codes are used in calculations due to the long computational time… read more here.

Keywords: resonance self; effect; self shielding; self ... See more keywords
Photo from wikipedia

Self-shielding effect of double heterogeneity for plutonium burner HTGR design

Sign Up to like & get
recommendations!
Published in 2020 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2019.107182

Abstract: Abstract The investigation on self-shielding effect of double heterogeneity for plutonium burner High Temperature Gas-cooled Reactor (HTGR) design has been performed. Plutonium burner HTGR designed in the previous study by using the advantage of double… read more here.

Keywords: shielding effect; self shielding; double heterogeneity; plutonium burner ... See more keywords
Photo by priscilladupreez from unsplash

A lumped parameter method of characteristics approach and multigroup kernels applied to the subgroup self-shielding calculation in MPACT

Sign Up to like & get
recommendations!
Published in 2017 at "Nuclear Engineering and Technology"

DOI: 10.1016/j.net.2017.07.006

Abstract: Abstract An essential component of the neutron transport solver is the resonance self-shielding calculation used to determine equivalence cross sections. The neutron transport code, MPACT, is currently using the subgroup self-shielding method, in which the… read more here.

Keywords: shielding calculation; lumped parameter; method; self shielding ... See more keywords
Photo by jareddrice from unsplash

Evaluation of Radiation Shielding Requirements and Self-shielding Characteristics for a Novel Radiosurgery System

Sign Up to like & get
recommendations!
Published in 2021 at "Health Physics"

DOI: 10.1097/hp.0000000000001465

Abstract: Abstract In order to provide safe operating conditions for radiation workers and the public at large, the radiation shielding for radiotherapy treatment rooms will have to be determined by an expert physicist according to the… read more here.

Keywords: self shielding; radiation; radiosurgery system; radiation shielding ... See more keywords