Articles with "serial dilution" as a keyword



Photo by imagoiq from unsplash

Ferrowax microvalves for fully automated serial dilution on centrifugal microfluidic platforms.

Sign Up to like & get
recommendations!
Published in 2021 at "Biotechnology journal"

DOI: 10.1002/biot.202100131

Abstract: We herein describe a centrifugal microfluidic system to accomplish a fully automated serial dilution. The liquid flow on the disc was regulated by utilizing ferrowax microvalves systematically integrated into the channels within specially designed metering… read more here.

Keywords: dilution; fully automated; ferrowax microvalves; centrifugal microfluidic ... See more keywords
Photo from wikipedia

Tail or artefact? Illustration of the impact that uncertainty of the serial dilution and cell enumeration methods has on microbial inactivation.

Sign Up to like & get
recommendations!
Published in 2019 at "Food research international"

DOI: 10.1016/j.foodres.2019.01.059

Abstract: The estimation of the concentration of microorganisms in a sample is crucial for food microbiology. For instance, it is essential for prevalence studies, challenge tests (growth and/or inactivation studies) or microbial risk assessment. The application… read more here.

Keywords: methodology; uncertainty; inactivation; uncertainty serial ... See more keywords
Photo by abeosorio from unsplash

The Aβ aggregation modulator MRZ-99030 prevents and even reverses synaptotoxic effects of Aβ1-42 on LTP even following serial dilution to a 500:1 stoichiometric excess of Aβ1-42, suggesting a beneficial prion-like seeding mechanism

Sign Up to like & get
recommendations!
Published in 2020 at "Neuropharmacology"

DOI: 10.1016/j.neuropharm.2020.108267

Abstract: MRZ-99030 (GAL-101) is a small molecule that promotes the formation of off-pathway, non-toxic amorphous clusters of Aβ thereby reducing the amount of toxic soluble oligomeric Aβ species. MRZ-99030 clearly prevents synaptotoxic effects of Aβ1-42 oligomers… read more here.

Keywords: mrz 99030; mrz; synaptotoxic effects; stoichiometric excess ... See more keywords
Photo by miracleday from unsplash

Multistep SlipChip for the Generation of Serial Dilution Nanoliter Arrays and Hepatitis B Viral Load Quantification by Digital Loop Mediated Isothermal Amplification.

Sign Up to like & get
recommendations!
Published in 2019 at "Analytical chemistry"

DOI: 10.1021/acs.analchem.9b01270

Abstract: Serial dilution is a commonly used technique that generates a low-concentration working sample from a high-concentration stock solution and is used to set up screening conditions over a large dynamic range for biological study, optimization… read more here.

Keywords: dilution nanoliter; dilution; nanoliter arrays; multistep slipchip ... See more keywords