Sign Up to like & get
recommendations!
1
Published in 2017 at "International Transactions on Electrical Energy Systems"
DOI: 10.1002/etep.2253
Abstract: DFIG is generally used in wind turbines because of its many advantages. However, DFIGs are sensitive to the network faults. When a fault occurs, the DFIG rotor current is increased and its converters may be…
read more here.
Keywords:
fault;
dfig;
wind;
enhancement sfcl ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2017 at "Canadian Journal of Electrical and Computer Engineering"
DOI: 10.1109/cjece.2017.2690829
Abstract: Regarding the permanent-magnet synchronous generator (PMSG)-based wind turbine system, this paper proposes a modified flux-coupling-type superconducting fault current limiter (SFCL) to enhance its fault ride-through (FRT) performance. The modified SFCL’s structural principle and theoretical influence…
read more here.
Keywords:
fault;
modified flux;
ride;
pmsg ... See more keywords
Photo by samdc from unsplash
Sign Up to like & get
recommendations!
1
Published in 2018 at "IEEE Transactions on Applied Superconductivity"
DOI: 10.1109/tasc.2017.2775566
Abstract: In this paper, a flux-coupling-type superconducting fault current limiter (SFCL) is suggested to protect a 15-MW class doubly fed induction generator (DFIG)-based wind farm. Detailed conceptual design and performance evaluation of the SFCL are conducted.…
read more here.
Keywords:
wind farm;
coupling type;
dfig based;
flux coupling ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "IEEE Transactions on Applied Superconductivity"
DOI: 10.1109/tasc.2018.2793922
Abstract: Superconducting fault current limiter (SFCL) is an efficient way to solve the short-circuit problems in modern power systems. A flux-coupling-type SFCL (FC-SFCL) based on disconnecting coupling windings for current reduction has been developed in this…
read more here.
Keywords:
electromagnetic design;
type sfcl;
coupling type;
flux coupling ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2018 at "IEEE Transactions on Applied Superconductivity"
DOI: 10.1109/tasc.2018.2821362
Abstract: Integrating permanent magnet synchronous generator (PMSG) wind turbines with DC microgrids have attracted a great attention due to the inherent merits of DC systems. However, under the fault conditions, the excessive energy during fault will…
read more here.
Keywords:
turbines microgrids;
fault;
pmsg;
pmsg wind ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2018 at "IEEE Transactions on Applied Superconductivity"
DOI: 10.1109/tasc.2018.2824840
Abstract: As a typical inductive type superconductive fault current limiter (SFCL), the saturated iron-core SFCL (SI-SFCL) is very important to the safety of the VSC-HVDC system. Considering that the high-induced voltage of the superconductive winding may…
read more here.
Keywords:
hvdc system;
fault current;
vsc hvdc;
sfcl ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2019 at "IEEE Transactions on Applied Superconductivity"
DOI: 10.1109/tasc.2018.2880325
Abstract: A compact 154-kV superconducting fault current limiters (SFCL) system has been developed by Korea Electric Power Corporation and led to a primary prototype being tested for three months at Gochang Power Test Center. Due to…
read more here.
Keywords:
compact 154;
system;
sfcl;
test ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2019 at "IEEE Transactions on Applied Superconductivity"
DOI: 10.1109/tasc.2019.2892519
Abstract: The dc fault current has a high amplitude and a fast rising speed, therefore with regard to the hybrid dc circuit breaker, it is hard to meet the requirement of a high breaking capacity while…
read more here.
Keywords:
sfcl;
circuit breaker;
circuit;
active sfcl ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2020 at "IEEE Transactions on Applied Superconductivity"
DOI: 10.1109/tasc.2020.2975748
Abstract: The resistive superconducting fault current limiter (R-SFCL) is considered as a promising protection device to restrict the DC fault current in modular multilevel converter based high voltage direct current (MMC-HVDC) system. One bottleneck of R-SFCL…
read more here.
Keywords:
system;
sfcl;
mmc hvdc;
shunt resistor ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2021 at "Journal of Microwaves, Optoelectronics and Electromagnetic Applications"
DOI: 10.1590/2179-10742021v20i21076
Abstract: Superconducting Fault Current Limiter (SFCL) modules with distinct arrangements have been investigated, seeking design and performance enhancements. In this context, this work aims to propose a design for resistive SFCL (R-SFCL) modules, using RE-Ba-Cu-O high-temperature…
read more here.
Keywords:
time;
sfcl;
short circuit;
circuit recovery ... See more keywords