Articles with "sfcl" as a keyword



Photo by schwiet from unsplash

Investigation and enhancement of SFCL impacts on DFIG‐based wind turbine during fault and post‐fault

Sign Up to like & get
recommendations!
Published in 2017 at "International Transactions on Electrical Energy Systems"

DOI: 10.1002/etep.2253

Abstract: DFIG is generally used in wind turbines because of its many advantages. However, DFIGs are sensitive to the network faults. When a fault occurs, the DFIG rotor current is increased and its converters may be… read more here.

Keywords: fault; dfig; wind; enhancement sfcl ... See more keywords
Photo by kellysikkema from unsplash

Study of a Modified Flux-Coupling-Type SFCL for Efficient Fault Ride-Through in a PMSG Wind Turbine Under Different Types of Faults

Sign Up to like & get
recommendations!
Published in 2017 at "Canadian Journal of Electrical and Computer Engineering"

DOI: 10.1109/cjece.2017.2690829

Abstract: Regarding the permanent-magnet synchronous generator (PMSG)-based wind turbine system, this paper proposes a modified flux-coupling-type superconducting fault current limiter (SFCL) to enhance its fault ride-through (FRT) performance. The modified SFCL’s structural principle and theoretical influence… read more here.

Keywords: fault; modified flux; ride; pmsg ... See more keywords
Photo by samdc from unsplash

Conceptual Design and Performance Evaluation of a 35-kV/500-A Flux-Coupling-Type SFCL for Protection of a DFIG-Based Wind Farm

Sign Up to like & get
recommendations!
Published in 2018 at "IEEE Transactions on Applied Superconductivity"

DOI: 10.1109/tasc.2017.2775566

Abstract: In this paper, a flux-coupling-type superconducting fault current limiter (SFCL) is suggested to protect a 15-MW class doubly fed induction generator (DFIG)-based wind farm. Detailed conceptual design and performance evaluation of the SFCL are conducted.… read more here.

Keywords: wind farm; coupling type; dfig based; flux coupling ... See more keywords
Photo by edhoradic from unsplash

Electromagnetic Design and Performance Analysis of a Flux-Coupling-Type SFCL

Sign Up to like & get
recommendations!
Published in 2018 at "IEEE Transactions on Applied Superconductivity"

DOI: 10.1109/tasc.2018.2793922

Abstract: Superconducting fault current limiter (SFCL) is an efficient way to solve the short-circuit problems in modern power systems. A flux-coupling-type SFCL (FC-SFCL) based on disconnecting coupling windings for current reduction has been developed in this… read more here.

Keywords: electromagnetic design; type sfcl; coupling type; flux coupling ... See more keywords
Photo by gieffe22 from unsplash

Fault Ride-Through Enhancement of PMSG Wind Turbines With DC Microgrids Using Resistive-Type SFCL

Sign Up to like & get
recommendations!
Published in 2018 at "IEEE Transactions on Applied Superconductivity"

DOI: 10.1109/tasc.2018.2821362

Abstract: Integrating permanent magnet synchronous generator (PMSG) wind turbines with DC microgrids have attracted a great attention due to the inherent merits of DC systems. However, under the fault conditions, the excessive energy during fault will… read more here.

Keywords: turbines microgrids; fault; pmsg; pmsg wind ... See more keywords
Photo by danedeaner from unsplash

Study of the Application of Active Saturated Iron-Core Superconductive Fault Current Limiters in the VSC-HVDC System

Sign Up to like & get
recommendations!
Published in 2018 at "IEEE Transactions on Applied Superconductivity"

DOI: 10.1109/tasc.2018.2824840

Abstract: As a typical inductive type superconductive fault current limiter (SFCL), the saturated iron-core SFCL (SI-SFCL) is very important to the safety of the VSC-HVDC system. Considering that the high-induced voltage of the superconductive winding may… read more here.

Keywords: hvdc system; fault current; vsc hvdc; sfcl ... See more keywords
Photo by saikanthv from unsplash

Development and Long-Term Test of a Compact 154-kV SFCL

Sign Up to like & get
recommendations!
Published in 2019 at "IEEE Transactions on Applied Superconductivity"

DOI: 10.1109/tasc.2018.2880325

Abstract: A compact 154-kV superconducting fault current limiters (SFCL) system has been developed by Korea Electric Power Corporation and led to a primary prototype being tested for three months at Gochang Power Test Center. Due to… read more here.

Keywords: compact 154; system; sfcl; test ... See more keywords
Photo by jsrm99 from unsplash

Research on the Parameter Matching Between Active SI-SFCL and DC Circuit Breaker in DC systems

Sign Up to like & get
recommendations!
Published in 2019 at "IEEE Transactions on Applied Superconductivity"

DOI: 10.1109/tasc.2019.2892519

Abstract: The dc fault current has a high amplitude and a fast rising speed, therefore with regard to the hybrid dc circuit breaker, it is hard to meet the requirement of a high breaking capacity while… read more here.

Keywords: sfcl; circuit breaker; circuit; active sfcl ... See more keywords
Photo by averey from unsplash

Analysis of R-SFCL With Shunt Resistor in MMC-HVDC System Using Novel R-Q Method

Sign Up to like & get
recommendations!
Published in 2020 at "IEEE Transactions on Applied Superconductivity"

DOI: 10.1109/tasc.2020.2975748

Abstract: The resistive superconducting fault current limiter (R-SFCL) is considered as a promising protection device to restrict the DC fault current in modular multilevel converter based high voltage direct current (MMC-HVDC) system. One bottleneck of R-SFCL… read more here.

Keywords: system; sfcl; mmc hvdc; shunt resistor ... See more keywords
Photo by jontyson from unsplash

Short Circuit and Recovery Time Tests in a helical bifilar R-SFCL module

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of Microwaves, Optoelectronics and Electromagnetic Applications"

DOI: 10.1590/2179-10742021v20i21076

Abstract: Superconducting Fault Current Limiter (SFCL) modules with distinct arrangements have been investigated, seeking design and performance enhancements. In this context, this work aims to propose a design for resistive SFCL (R-SFCL) modules, using RE-Ba-Cu-O high-temperature… read more here.

Keywords: time; sfcl; short circuit; circuit recovery ... See more keywords