Published in 2018 at "Earthquake Engineering and Engineering Vibration"
DOI: 10.1007/s11803-018-0436-y
Abstract: The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a…
read more here.
Keywords:
centering precast;
frame shear;
shear walls;
self centering ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2019 at "KSCE Journal of Civil Engineering"
DOI: 10.1007/s12205-019-1170-3
Abstract: This paper describes the study of steel tube reinforced concrete (STRC) shear walls with a low shear-span ratio, in which steel tubes are embedded in the web of the shear wall. The addition of these…
read more here.
Keywords:
steel;
tube reinforced;
shear walls;
strc shear ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2020 at "Ksce Journal of Civil Engineering"
DOI: 10.1007/s12205-020-2305-2
Abstract: Corrugated steel plate shear walls (CoSPSWs), which consist of corrugated infill steel wall panels and steel boundary frames, could be used as lateral force-resisting systems for mid- to high-rise buildings. In seismic design, the fundamental…
read more here.
Keywords:
fundamental period;
period;
shear walls;
steel ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2018 at "Archives of Civil and Mechanical Engineering"
DOI: 10.1016/j.acme.2018.06.012
Abstract: Abstract Regarding high ductility and potential of steel plate shear walls in energy absorption, they are required to be very thin in thickness especially in upper floors of the building in order to resist lateral…
read more here.
Keywords:
shear strength;
plate shear;
plate;
shear walls ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2021 at "Construction and Building Materials"
DOI: 10.1016/j.conbuildmat.2021.123103
Abstract: Abstract Timber-framed shear walls are designed to resist the lateral loads on a building from wind and earthquake. Many regions around the world have developed standard test methods for evaluating the performance of timber-framed shear…
read more here.
Keywords:
timber framed;
performance;
shear walls;
test ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2019 at "Engineering Failure Analysis"
DOI: 10.1016/j.engfailanal.2019.02.032
Abstract: Abstract Buildings can have heavy damages or collapse because of severe earthquakes. Previous studies showed that structural damage due to earthquake is the cause of large displacement. Shear walls in the buildings ensure safety against…
read more here.
Keywords:
earthquake;
effect shear;
van 2011;
2011 earthquake ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Engineering Structures"
DOI: 10.1016/j.engstruct.2017.01.004
Abstract: Abstract This paper presents an experimental and numerical study of semi-supported steel plate shear walls which are connected to frame beams and a pair of secondary columns. As the infill plates are not connected to…
read more here.
Keywords:
semi supported;
experimental numerical;
shear walls;
steel ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2018 at "Engineering Structures"
DOI: 10.1016/j.engstruct.2017.11.006
Abstract: Abstract This paper presents the hysteretic behaviour of three 1/3-scale three-storey steel fibre reinforced concrete (SFRC) coupled shear walls (CSWs) under cyclic loads. The deformation, ductility, energy dissipation, stiffness and crack propagation of the specimens…
read more here.
Keywords:
hysteretic behaviour;
cyclic loads;
steel fibre;
coupled shear ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "Engineering Structures"
DOI: 10.1016/j.engstruct.2018.01.040
Abstract: Abstract In this study, an innovative composite shear wall, comprised of boundary Concrete Filled Steel Tubular (CFST) columns, and Reinforced Concrete (RC) walls embedded with multiple steel plates has been developed. Seven specimens were investigated…
read more here.
Keywords:
steel plates;
multiple steel;
cfst columns;
shear walls ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2019 at "Engineering Structures"
DOI: 10.1016/j.engstruct.2019.04.035
Abstract: Abstract Past experimental studies have demonstrated that reinforced masonry shear walls (RMSWs) can provide adequate ductility and energy dissipation capacity when acting as the seismic force-resisting system in low-rise buildings. However, slender RMSWs used for…
read more here.
Keywords:
plane;
shear walls;
plane instability;
boundary elements ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2019 at "Engineering Structures"
DOI: 10.1016/j.engstruct.2019.04.052
Abstract: Abstract The aim of this paper was to investigate the seismic behavior of shear walls reinforced with CFRP (carbon fiber reinforced polymer) bars as longitudinal reinforcement. Three full-scale shear walls with same geometry and dimension…
read more here.
Keywords:
fiber reinforced;
cyclic lateral;
shear walls;
polymer bars ... See more keywords