Articles with "socket" as a keyword



Photo from wikipedia

Approach for gait analysis in persons with limb loss including residuum and prosthesis socket dynamics.

Sign Up to like & get
recommendations!
Published in 2018 at "International journal for numerical methods in biomedical engineering"

DOI: 10.1002/cnm.2936

Abstract: Musculoskeletal modeling and marker-based motion capture techniques are commonly used to quantify the motions of body segments, and the forces acting on them during human gait. However, when these techniques are applied to analyze the… read more here.

Keywords: gait analysis; limb loss; socket;
Photo by kellysikkema from unsplash

Medial patellofemoral ligament (MPFL) reconstruction technique using an epiphyseal femoral socket with fluoroscopic guidance helps avoid physeal injury in skeletally immature patients

Sign Up to like & get
recommendations!
Published in 2019 at "Knee Surgery, Sports Traumatology, Arthroscopy"

DOI: 10.1007/s00167-019-05412-7

Abstract: PurposeThe purpose of this study was to assess the physeal safety associated with the use of an epiphyseal femoral socket for paediatric medial patellofemoral ligament (MPFL) reconstruction.MethodsFifty-four knees in 49 skeletally immature patients underwent physeal-sparing… read more here.

Keywords: mpfl reconstruction; epiphyseal femoral; socket; femoral socket ... See more keywords
Photo by anniespratt from unsplash

Study of conjunctival flora in anophthalmic patients: influence on the comfort of the socket

Sign Up to like & get
recommendations!
Published in 2017 at "Graefe's Archive for Clinical and Experimental Ophthalmology"

DOI: 10.1007/s00417-017-3708-8

Abstract: PurposeTo investigate the relationship between conjunctival flora and comfort of the socket in anophthalmic patients.MethodsA cross-sectional clinical study including 60 patients with unilateral anophthalmia who wear a prosthetic eye. From each patient three microbiological samples… read more here.

Keywords: prosthesis; socket; conjunctival flora; comfort socket ... See more keywords
Photo by mertguller from unsplash

Effect of CBX7 deficiency on the socket healing after tooth extractions

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Bone and Mineral Metabolism"

DOI: 10.1007/s00774-018-0958-4

Abstract: CBX7 is shown to down-regulate the expression of osteopontin (OPN) that is associated with osteoblast function. Here, we studied the role of CBX7 in the wound healing of tooth extraction socket in which osteoblast activity… read more here.

Keywords: cbx7 mice; socket; bone; cbx7 ... See more keywords
Photo by aaronburden from unsplash

To assess the efficacy of socket plug technique using platelet rich fibrin with or without the use of bone substitute in alveolar ridge preservation: a prospective randomised controlled study

Sign Up to like & get
recommendations!
Published in 2018 at "Oral and Maxillofacial Surgery"

DOI: 10.1007/s10006-018-0680-3

Abstract: AimThe purpose of this study is to evaluate the efficacy of Platelet Rich Fibrin (PRF) as a socket plug with or without use of Plaster of Paris (POP) as bone substitute to preserve the alveolar… read more here.

Keywords: socket; bone substitute; study; socket plug ... See more keywords
Photo from wikipedia

Predictive prosthetic socket design: part 1—population-based evaluation of transtibial prosthetic sockets by FEA-driven surrogate modelling

Sign Up to like & get
recommendations!
Published in 2019 at "Biomechanics and Modeling in Mechanobiology"

DOI: 10.1007/s10237-019-01195-5

Abstract: It has been proposed that finite element analysis can complement clinical decision making for the appropriate design and manufacture of prosthetic sockets for amputees. However, clinical translation has not been achieved, in part due to… read more here.

Keywords: prosthetic socket; socket; part; prosthetic sockets ... See more keywords
Photo by oisinconolly from unsplash

Development of a Sensor to Measure Stump/Socket Interfacial Shear Stresses in a Lower-Extremity Amputee

Sign Up to like & get
recommendations!
Published in 2018 at "International Journal of Precision Engineering and Manufacturing"

DOI: 10.1007/s12541-018-0106-z

Abstract: The aim of this study was to develop and validate a sensor to measure interfacial shear forces on the residual limb in the socket of lower-extremity amputees. The sensor consisted of three layers: upper and… read more here.

Keywords: lower extremity; socket; stump socket; interfacial shear ... See more keywords
Photo by kellysikkema from unsplash

Comparison of Immediate Implant Placement Following Extraction with and Without Socket-Shield Technique in Esthetic Region

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Maxillofacial and Oral Surgery"

DOI: 10.1007/s12663-019-01272-3

Abstract: Immediate implant with socket shield and immediate implant without socket shield are the two techniques which can be used to preserve the already thin labial bone in the esthetic region, thus eliminating the need for… read more here.

Keywords: implant placement; socket; without socket; shield technique ... See more keywords
Photo from wikipedia

Systematic Review of Studies Examining Transtibial Prosthetic Socket Pressures with Changes in Device Alignment

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of Medical and Biological Engineering"

DOI: 10.1007/s40846-017-0217-5

Abstract: Suitable lower-limb prosthetic sockets must provide an adequate distribution of the pressures created from standing and ambulation. A systematic search for articles reporting socket pressure changes in response to device alignment perturbation was carried out,… read more here.

Keywords: device alignment; systematic review; socket; review studies ... See more keywords
Photo from wikipedia

Quasi-static tests of CFST embedded RC column-to-precast cap beam with socket connection

Sign Up to like & get
recommendations!
Published in 2021 at "Engineering Structures"

DOI: 10.1016/j.engstruct.2021.112443

Abstract: Abstract The seismic behavior of an embedded concrete-filled steel tubes (CFST) precast column-to-cap beam socket connection of a practical engineering project was investigated through 1:3-scale quasi-static tests. The precast column and cap beam was integrated… read more here.

Keywords: socket; column; cap beam; connection ... See more keywords
Photo by thisisengineering from unsplash

Experimental thermal analysis of a novel prosthetic socket along with silicone and PCM liners.

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of biomechanics"

DOI: 10.1016/j.jbiomech.2020.109788

Abstract: Prosthetic liners and sockets insulate a residual limb, causing excessive heat, sweating, skin irritation and maceration. Circulation of a fluid through the socket wall has been shown to have positive cooling effects on the internal… read more here.

Keywords: prosthetic socket; socket; pcm liners; novel prosthetic ... See more keywords