Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2019 at "Mikrochimica Acta"
DOI: 10.1007/s00604-019-3830-x
Abstract: A new approach is presented for the design of ion selective electrodes. Ruthenium dioxide nanoparticles were incorporated into solid-contact electrodes, and their properties were studied for the case of pH-selective electrodes. The use of the…
read more here.
Keywords:
ruthenium;
ruthenium dioxide;
selective electrodes;
solid contact ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Analytica chimica acta"
DOI: 10.1016/j.aca.2017.05.032
Abstract: A solid-contact ion-selective electrode (SC-ISE) for potassium with MoO2 microspheres as ion-to-electron transducer is described. MoO2 microsphers can be synthesized via the reduction of MoO3 nanobelts in an isopropanol solvent with a mild process, and…
read more here.
Keywords:
potassium;
ion;
moo2 microspheres;
solid contact ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2020 at "Analytica chimica acta"
DOI: 10.1016/j.aca.2020.06.044
Abstract: Nano-layered solid-contact potassium-selective electrodes (K+-ISEs) were explored as model ion-selective electrodes for their practical use in clinical analysis. The ultra-thin ISEs ought to be manufactured in a highly reproducible manner, potentially making them suitable for…
read more here.
Keywords:
selective electrodes;
layered solid;
ion selective;
ion ... See more keywords
Photo by cdc from unsplash
Sign Up to like & get
recommendations!
0
Published in 2021 at "Electrochimica Acta"
DOI: 10.1016/j.electacta.2020.137566
Abstract: Abstract In this work, the coulometric response of nitrate, perchlorate, and sulfate solid-contact anion-sensitive electrodes was investigated. The coulometric transduction method was originally introduced and so far mainly studied for solid-contact cation-selective sensors using poly(3,4-ethylenedioxythiophene)…
read more here.
Keywords:
sensitive electrodes;
coulometric response;
anion sensitive;
solid contact ... See more keywords
Photo from archive.org
Sign Up to like & get
recommendations!
0
Published in 2020 at "Journal of The European Ceramic Society"
DOI: 10.1016/j.jeurceramsoc.2019.10.007
Abstract: Abstract The wetting of Ni-Hf and Ni-Cr-Hf alloys on sapphire has been studied in this work. Sapphire represents a “simple” and ideal case adopted for better understanding the basic phenomena involved in liquid/solid contact during…
read more here.
Keywords:
sapphire;
wetting interfacial;
liquid solid;
solid contact ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2019 at "Synthetic Metals"
DOI: 10.1016/j.synthmet.2019.01.008
Abstract: Abstract Hydrophobic polyaniline-polystyrene microfiber films (e-PANI-PS) with a water contact angle of 104° were successfully prepared by electrospinning, then applied as a novel ion-to-electron transducer in solid-contact Pb2+ ion selective electrodes (Pb2+-ISEs). The GC/e-PANI-PS/Pb2+-ISE exhibited…
read more here.
Keywords:
contact;
solid contact;
hydrophobic polyaniline;
ion electron ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2018 at "Talanta"
DOI: 10.1016/j.talanta.2018.04.056
Abstract: We report here the fabrication of solid-contact calcium-selective electrodes (Ca2+-SCISEs) made of a polyurethane acrylate ion-selective membrane (ISM) that was covalently attached to the underlying ion-to-electron transducer (solid-contact). Methacrylate-functionalized poly(3,4-ethylenedioxythiophene) (Meth-PEDOT) and Meth-PEDOT films containing…
read more here.
Keywords:
polyurethane acrylate;
calcium selective;
selective electrodes;
solid contact ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2021 at "Analytical chemistry"
DOI: 10.1021/acs.analchem.1c04722
Abstract: By its nature, a traditional potentiometric cell composed of an Ag/AgCl-based reference electrode and a solid-contact indicating electrode is not symmetric. This results in undesirable potential drifts in response to a common perturbation such as…
read more here.
Keywords:
solid contact;
symmetry;
potentiometric cell;
cell ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2022 at "Analytical chemistry"
DOI: 10.1021/acs.analchem.1c04748
Abstract: The performance criteria for the design of all-solid-state ion-selective electrodes mainly include high electrode-to-electrode reproducibility and a low potential drift. Here, we introduce nickel cobalt sulfide (NiCo2S4) as a solid contact for ion-to-electron transduction based…
read more here.
Keywords:
solid contact;
ion selective;
contact;
nico2s4 solid ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2022 at "Analytical Chemistry"
DOI: 10.1021/acs.analchem.2c00395
Abstract: Solid-contact ion-selective electrodes (SCISEs) can overcome essential limitations of their counterparts based on liquid contacts. However, attaining a highly reproducible and predictable E0, especially between different fabrication batches, turned out to be difficult even with…
read more here.
Keywords:
solid contact;
reproducibility;
ion selective;
contact ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "Analytical chemistry"
DOI: 10.1021/acs.analchem.2c01728
Abstract: In potentiometric sensing, the preparation of the electrodes preceding a measurement is often the most time-consuming step. Eliminating the conditioning process can significantly speed up the preparation procedure, but it can also compromise the need…
read more here.
Keywords:
solid contact;
unconditioned symmetric;
potentiometric sensing;
contact ... See more keywords