Articles with "spin echo" as a keyword



Photo by sarahsosiak from unsplash

Self‐Calibrating Wave‐Encoded Variable‐Density Single‐Shot Fast Spin Echo Imaging

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Magnetic Resonance Imaging"

DOI: 10.1002/jmri.25853

Abstract: It is highly desirable in clinical abdominal MR scans to accelerate single‐shot fast spin echo (SSFSE) imaging and reduce blurring due to T2 decay and partial‐Fourier acquisition. read more here.

Keywords: single shot; spin echo; shot fast; fast spin ... See more keywords
Photo by sarahsosiak from unsplash

Three‐dimensional spin‐echo‐based black‐blood MRA in the detection of vasospasm following subarachnoid hemorrhage

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Magnetic Resonance Imaging"

DOI: 10.1002/jmri.26231

Abstract: Black‐blood MR angiography (BBMRA), which utilizes a non‐T1 contrast spin‐echo type technique, has been expected to overcome several issues associated with time‐of‐flight (TOF) MRA. read more here.

Keywords: black blood; dimensional spin; spin echo; three dimensional ... See more keywords
Photo from wikipedia

Magnetic Resonance Elastography of Intervertebral Discs: Spin‐Echo Echo‐Planar Imaging Sequence Validation

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Magnetic Resonance Imaging"

DOI: 10.1002/jmri.28151

Abstract: Magnetic resonance elastography (MRE) is an imaging technique that can noninvasively assess the shear properties of the intervertebral disc (IVD). Unlike the standard gradient recalled echo (GRE) MRE technique, a spin‐echo echo‐planar imaging (SE‐EPI) sequence… read more here.

Keywords: magnetic resonance; spin echo; resonance elastography; echo echo ... See more keywords
Photo by vlisidis from unsplash

Towards perfect NMR: Spin‐echo versus perfect‐echo building blocks

Sign Up to like & get
recommendations!
Published in 2019 at "Magnetic Resonance in Chemistry"

DOI: 10.1002/mrc.4776

Abstract: The development of new tools to improve the quality of nuclear magnetic resonance (NMR) spectra is a challenging task. The concept of “perfect NMR” includes the design of robust pulse sequences that allow an investigator… read more here.

Keywords: perfect nmr; building blocks; echo; spin echo ... See more keywords
Photo by tabithabrooke from unsplash

Amide proton transfer imaging of brain tumors using a self‐corrected 3D fast spin‐echo dixon method: Comparison With separate B0 correction

Sign Up to like & get
recommendations!
Published in 2017 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.26322

Abstract: To assess the quantitative performance of three‐dimensional (3D) fast spin‐echo (FSE) Dixon amide proton transfer (APT) imaging of brain tumors compared with B0 correction with separate mapping methods. read more here.

Keywords: fast spin; imaging brain; amide proton; proton transfer ... See more keywords
Photo by sarahsosiak from unsplash

The effect of concomitant fields in fast spin echo acquisition on asymmetric MRI gradient systems

Sign Up to like & get
recommendations!
Published in 2018 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.26789

Abstract: To investigate the effect of the asymmetric gradient concomitant fields (CF) with zeroth and first‐order spatial dependence on fast/turbo spin‐echo acquisitions, and to demonstrate the effectiveness of their real‐time compensation. read more here.

Keywords: fields fast; concomitant fields; effect concomitant; gradient ... See more keywords
Photo from wikipedia

Performance of a fast and high‐resolution multi‐echo spin‐echo sequence for prostate T2 mapping across multiple systems

Sign Up to like & get
recommendations!
Published in 2018 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.26816

Abstract: To evaluate the performance of a multi‐echo spin‐echo sequence with k‐t undersampling scheme (k‐t T2) in prostate cancer. read more here.

Keywords: echo spin; multi echo; performance; echo sequence ... See more keywords
Photo from wikipedia

A 2D spiral turbo‐spin‐echo technique

Sign Up to like & get
recommendations!
Published in 2018 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.27171

Abstract: 2D turbo‐spin‐echo (TSE) is widely used in the clinic for neuroimaging. However, the long refocusing radiofrequency pulse train leads to high specific absorption rate (SAR) and alters the contrast compared to conventional spin‐echo. The purpose… read more here.

Keywords: technique; spin echo; turbo spin; spin ... See more keywords
Photo from wikipedia

Navigator‐based reacquisition and estimation of motion‐corrupted data: Application to multi‐echo spin echo for carotid wall MRI

Sign Up to like & get
recommendations!
Published in 2019 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.28063

Abstract: To assess whether artifacts in multi‐slice multi‐echo spin echo neck imaging, thought to be caused by brief motion events such as swallowing, can be corrected by reacquiring corrupted central k‐space data and estimating the remainder… read more here.

Keywords: echo spin; spin echo; multi echo;
Photo by sarahsosiak from unsplash

Multi‐spin echo T2 relaxation imaging with compressed sensing (METRICS) for rapid myelin water imaging

Sign Up to like & get
recommendations!
Published in 2020 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.28199

Abstract: Myelin water imaging (MWI) provides a valuable biomarker for myelin, but clinical application has been restricted by long acquisition times. Accelerating the standard multi‐echo T2 acquisition with gradient echoes (GRASE) or by 2D multi‐slice data… read more here.

Keywords: multi spin; compressed sensing; water imaging; spin echo ... See more keywords
Photo from wikipedia

Diffusion‐prepared 3D gradient spin‐echo sequence for improved oscillating gradient diffusion MRI

Sign Up to like & get
recommendations!
Published in 2020 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.28401

Abstract: Oscillating gradient (OG) enables the access of short diffusion times for time‐dependent diffusion MRI (dMRI); however, it poses several technical challenges for clinical use. This study proposes a 3D oscillating gradient–prepared gradient spin‐echo (OGprep‐GRASE) sequence… read more here.

Keywords: prepared gradient; gradient spin; diffusion; oscillating gradient ... See more keywords