Articles with "taper" as a keyword



Photo from wikipedia

Dual-taper modular hip implant: Investigation of 3-dimensional surface scans for component contact, shape, and fit

Sign Up to like & get
recommendations!
Published in 2018 at "Arthroplasty Today"

DOI: 10.1016/j.artd.2018.06.001

Abstract: Background The etiology of wear particle generation and subsequent corrosion in modular total hip arthroplasty implants likely begins with mechanical fretting. The purpose of this study was to determine geometric features of the male and… read more here.

Keywords: taper; surface; neck stem; modular hip ... See more keywords
Photo by guillaumedegermain from unsplash

Incorporating stand density effects in modeling the taper of red pine plantations

Sign Up to like & get
recommendations!
Published in 2020 at "Canadian Journal of Forest Research"

DOI: 10.1139/cjfr-2020-0064

Abstract: Taper models are used to estimate the diameter at any height along the bole of a tree. Individual tree volume can then be calculated based on these diameters and corresponding heights. As tree diam... read more here.

Keywords: effects modeling; taper; incorporating stand; density effects ... See more keywords
Photo from wikipedia

Stand up! Are normal weight-bearing forces sufficient for a 12/14 Morse taper locking in total hip arthroplasty?

Sign Up to like & get
recommendations!
Published in 2020 at "HIP International"

DOI: 10.1177/1120700020967000

Abstract: Background: The aim of this study was to investigate total hip arthroplasty (THA) Morse taper pull-off strengths after impaction prior to cyclical loading compared to cyclical loading alone. The practical relevance of the experiment is… read more here.

Keywords: hip arthroplasty; total hip; impaction; head ... See more keywords
Photo by owenbeard from unsplash

Taper Technology in Total Hip Arthroplasty

Sign Up to like & get
recommendations!
Published in 2017 at "JBJS Reviews"

DOI: 10.2106/jbjs.rvw.16.00073

Abstract: The taper junction comprises a male trunnion and female bore at specific taper angles, which join together in an interference cold weld fit.Studies have suggested that an impaction force of 4,000 N provides sufficient interference… read more here.

Keywords: taper; technology total; corrosion; taper technology ... See more keywords
Photo from wikipedia

Skeletal Muscle Adaptations and Performance Outcomes Following a Step and Exponential Taper in Strength Athletes

Sign Up to like & get
recommendations!
Published in 2021 at "Frontiers in Physiology"

DOI: 10.3389/fphys.2021.735932

Abstract: Before major athletic events, a taper is often prescribed to facilitate recovery and enhance performance. However, it is unknown which taper model is most effective for peaking maximal strength and positively augmenting skeletal muscle. Thus,… read more here.

Keywords: strength; skeletal muscle; taper; muscle ... See more keywords
Photo from wikipedia

Does Low-Taper Root Canal Shaping Decrease the Risk of Root Fracture? A Systematic Review

Sign Up to like & get
recommendations!
Published in 2022 at "Dentistry Journal"

DOI: 10.3390/dj10060094

Abstract: Minimal root-canal preparation has been suggested to reduce the risk of root fracture, but as a result, satisfactory cleaning and shaping do not take place. Large-scale taper instrumentation can contribute to removing infected tissue; however,… read more here.

Keywords: root; taper; root fracture; review ... See more keywords
Photo from wikipedia

The Mechanical Behavior of a Screwless Morse Taper Implant–Abutment Connection: An In Vitro Study

Sign Up to like & get
recommendations!
Published in 2022 at "Materials"

DOI: 10.3390/ma15093381

Abstract: The use of screwless Morse taper implant–abutment connections (IAC) might facilitate the clinician’s work by eliminating the mechanical complications associated with the retention screw. The aim of this study is to evaluate the effect of… read more here.

Keywords: taper implant; taper; implant abutment; iac ... See more keywords
Photo from wikipedia

Development of Taper-in-Taper-Based Optical Fiber Sensors for Chemical and Biological Sensing

Sign Up to like & get
recommendations!
Published in 2023 at "Photonics"

DOI: 10.3390/photonics10050567

Abstract: This paper presents the development of taper-in-taper fiber (TITF)–optical fiber-based sensors for chemical and biological detection. TITF structure is a fiber structure formed by fabricating a taper again on the taper region of the traditional… read more here.

Keywords: taper; structure; taper taper; fiber ... See more keywords