Articles with "test specimens" as a keyword



Photo from wikipedia

Creep constraint analysis for test specimens with a wide range of dimensions and comparison with constraint of cracked pipes

Sign Up to like & get
recommendations!
Published in 2018 at "Engineering Fracture Mechanics"

DOI: 10.1016/j.engfracmech.2018.10.033

Abstract: Abstract Based on extensive three-dimensional finite element analyses and the unified creep constraint parameter Ac, systematic studies have been carried out to examine effects of a wide range of dimensions of test specimens (C(T), SEN(T)… read more here.

Keywords: creep constraint; range dimensions; constraint; test specimens ... See more keywords
Photo from wikipedia

CREEP RUPTURE BEHAVIOR OF STEEL PLATE INSERTION TYPE DRIFT PIN JOINT

Sign Up to like & get
recommendations!
Published in 2019 at "AIJ Journal of Technology and Design"

DOI: 10.3130/aijt.25.151

Abstract: Small clear test specimens with different width to pin-diameter ratio (l/d ) were loaded for creep rapture and time to failure was discussed in terms of the effect of length to pin-diameter ratio. The time… read more here.

Keywords: pin diameter; test specimens; diameter ratio; time failure ... See more keywords
Photo from wikipedia

Predicting Failure of Additively Manufactured Specimens with Holes

Sign Up to like & get
recommendations!
Published in 2023 at "Materials"

DOI: 10.3390/ma16062293

Abstract: Experimental and computational studies were conducted to predict failure loads of specimens containing different-sized holes made using the additive manufacturing (AM) technique. Two different types of test specimens were prepared. Flat specimens, manufactured from polylactic… read more here.

Keywords: failure additively; test specimens; predicting failure; additively manufactured ... See more keywords
Photo from wikipedia

Influence of Test Specimen Geometry and Water Soaking on the In Vitro Cytotoxicity of Orthocryl®, Orthocryl® LC, Loctite® EA 9483 and Polypropylene

Sign Up to like & get
recommendations!
Published in 2022 at "Molecules"

DOI: 10.3390/molecules27123949

Abstract: Depending on their composition, plastics have a cytotoxic potential that needs to be evaluated before they are used in dentistry, e.g., as orthodontic removable appliances. Relevant guidelines set out requirements that a potential new resin… read more here.

Keywords: test specimens; geometry; test; loctite 9483 ... See more keywords
Photo from wikipedia

Micro-shear bond strength of composite resin to glass ionomer cement using an alternative method to build up test specimens

Sign Up to like & get
recommendations!
Published in 2018 at "Indian Journal of Dental Research"

DOI: 10.4103/ijdr.ijdr_499_16

Abstract: Context: Despite the relevance of the sandwich technique, there are still doubts about the best adhesive strategy and surface treatment for glass ionomer cements (GICs). Aim: The aim of this study is to evaluate the… read more here.

Keywords: build test; alternative method; micro shear; method build ... See more keywords