Articles with "unstable pelvic" as a keyword



Photo from wikipedia

Minimally invasive internal fixator for unstable pelvic ring injuries with a pedicle screw–rod system: a retrospective study of 23 patients after 13.5 months

Sign Up to like & get
recommendations!
Published in 2018 at "Archives of Orthopaedic and Trauma Surgery"

DOI: 10.1007/s00402-018-3094-7

Abstract: PurposePelvic ring fractures are challenging injuries and require effective treatment due to the frequently compromised patient condition. The aim of this study was to evaluate the outcome of unstable pelvic ring injuries treated with a… read more here.

Keywords: pelvic ring; minimally invasive; screw rod; fixator ... See more keywords
Photo from wikipedia

Effectiveness and complications of primary C-clamp stabilization or external fixation for unstable pelvic fractures.

Sign Up to like & get
recommendations!
Published in 2019 at "Injury"

DOI: 10.1016/j.injury.2019.08.039

Abstract: BACKGROUND AND PURPOSE Unstable pelvic fractures frequently require emergency stabilization using a C-clamp or external (CC/EF) fixation. However, the effectiveness of this intervention and associated complications are still a matter of debate. PATIENTS AND METHODS… read more here.

Keywords: stabilization; fixation; pelvic fractures; clamp stabilization ... See more keywords
Photo from wikipedia

Update on open reduction and internal fixation of unstable pelvic fractures during pregnancy: case reports☆

Sign Up to like & get
recommendations!
Published in 2018 at "Revista Brasileira de Ortopedia"

DOI: 10.1016/j.rboe.2017.03.002

Abstract: This article aims to report four cases of unstable pelvic fractures in pregnant women treated by open reduction and internal fixation. Cases report The study included four cases of pregnant women with unstable pelvic fractures;… read more here.

Keywords: open reduction; reduction internal; unstable pelvic; pelvic fractures ... See more keywords
Photo from wikipedia

Re: External fixation of unstable pelvic fractures: a systematic review and meta‐analysis

Sign Up to like & get
recommendations!
Published in 2019 at "ANZ Journal of Surgery"

DOI: 10.1111/ans.15266

Abstract: We read with interest the recent article by Stewart et al., who concluded a systematic review and meta-analysis study that considered the external fixation of unstable pelvic fractures. In this study, it is indicated that… read more here.

Keywords: analysis; systematic review; meta; unstable pelvic ... See more keywords
Photo from wikipedia

Minimally Invasive 360° Fusion Using a Combination of INFIX and Minimally Invasive Spinopelvic Fixation by Intraoperative Computed Tomography Navigation for Unstable Pelvic Ring Fracture: A Technical Note

Sign Up to like & get
recommendations!
Published in 2023 at "Orthopaedic Surgery"

DOI: 10.1111/os.13713

Abstract: Fluoroscopy is often used in the surgery of unstable pelvic ring fractures, and improved safety in implant placement is an issue. An anterior subcutaneous pelvic fixator (INFIX) combined with a percutaneous screw has been reported… read more here.

Keywords: unstable pelvic; technical note; minimally invasive; fixation ... See more keywords
Photo from wikipedia

Early Experience with Reduction of Unstable Pelvic Fracture Using a Computer-Aided Reduction Frame

Sign Up to like & get
recommendations!
Published in 2018 at "BioMed Research International"

DOI: 10.1155/2018/7297635

Abstract: Purpose The optimal closed reduction technique for unstable pelvic fractures remains controversial. The purpose of this study is to verify the effectiveness and report early experiences with the reduction of unstable pelvic fractures using a… read more here.

Keywords: unstable pelvic; reduction; reduction frame; computer aided ... See more keywords
Photo from wikipedia

Is unrestricted weight bearing immediately after fixation of rotationally unstable pelvic fractures safe?

Sign Up to like & get
recommendations!
Published in 2022 at "BMC Musculoskeletal Disorders"

DOI: 10.1186/s12891-022-05299-5

Abstract: Introduction Rotationally unstable pelvic fractures treated with surgical fixation have traditionally been treated with restricted weight bearing on the affected side for 6–8 weeks post operatively. We have been developing pelvic fixation standards to allow for… read more here.

Keywords: pelvic fractures; unstable pelvic; fixation; rotationally unstable ... See more keywords
Photo from wikipedia

Multi-slice spiral computed tomography in diagnosing unstable pelvic fractures in elderly and effect of less invasive stabilization

Sign Up to like & get
recommendations!
Published in 2022 at "World Journal of Clinical Cases"

DOI: 10.12998/wjcc.v10.i14.4470

Abstract: BACKGROUND Older people are more likely to experience pelvic fractures than younger people. Multi-slice spiral computed tomography (CT) uses three-dimensional (3D) reconstruction technology to generate 3D images that can clearly demonstrate the 3D space of… read more here.

Keywords: slice spiral; pelvic fractures; multi slice; unstable pelvic ... See more keywords
Photo from academic.microsoft.com

Management of Hemodynamically Unstable Pelvic Ring Fractures

Sign Up to like & get
recommendations!
Published in 2020 at "Frontiers in Surgery"

DOI: 10.3389/fsurg.2020.601321

Abstract: Hemodynamically unstable pelvic fractures are challenging high-energy traumas. In many cases, these severely injured patients have additional traumatic injuries that also require a trauma surgeon's attention. However, these patients are often in extremis and require… read more here.

Keywords: hemodynamically unstable; management hemodynamically; physiology; ring fractures ... See more keywords