Articles with "vertebral body" as a keyword



Photo from wikipedia

Small cavity creation in the vertebral body reduces the rate of cement leakage during vertebroplasty

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of Orthopaedic Research"

DOI: 10.1002/jor.23215

Abstract: Cement leakage is the most common complication during vertebroplasty and may result in serious morbidity. Measures to reduce the rate of cement leakage are valuable ways to improve vertebroplasty safety. The present study aimed to… read more here.

Keywords: cement leakage; cement; vertebroplasty; vertebral body ... See more keywords
Photo from wikipedia

Development and inter-institutional validation of an automatic vertebral-body misalignment error detector for Cone-Beam CT guided radiotherapy.

Sign Up to like & get
recommendations!
Published in 2022 at "Medical physics"

DOI: 10.1002/mp.15927

Abstract: BACKGROUND In Cone-Beam Computed Tomography (CBCT) guided radiotherapy, off-by-one vertebral body misalignments are rare but serious errors which lead to wrong-site treatments. PURPOSE An automatic error detection algorithm was developed that uses a three-branch convolutional… read more here.

Keywords: vertebral body; radiotherapy; error; model ... See more keywords
Photo from wikipedia

Increased vertebral body area, disc and facet joint degeneration throughout the lumbar spine in patients with lumbosacral transitional vertebrae

Sign Up to like & get
recommendations!
Published in 2022 at "European Radiology"

DOI: 10.1007/s00330-022-08736-0

Abstract: Lumbosacral transitional vertebrae (LSTV), developmental spinal canal stenosis, lumbar disc and facet joint degeneration are all common lumbar spine conditions. This study explores the relationship between these entities. Five hundred and five patients (254 females,… read more here.

Keywords: vertebral body; facet joint; joint degeneration; degeneration ... See more keywords
Photo from wikipedia

Hybrid stabilization of unstable osteoporotic thoracolumbar vertebral body fractures: clinical and radiological outcome after a mean of 4 years

Sign Up to like & get
recommendations!
Published in 2019 at "European Spine Journal"

DOI: 10.1007/s00586-019-05957-8

Abstract: PurposeThe aim of this study was to evaluate midterm results after hybrid stabilization of unstable osteoporotic fractures of the thoracolumbar junction.MethodsThis retrospective study was performed at a level I trauma center. A total of 113… read more here.

Keywords: hybrid stabilization; reduction; loss; vertebral body ... See more keywords
Photo from wikipedia

Anterior column reconstruction of the thoracolumbar spine with a new modular PEEK vertebral body replacement device: retrospective clinical and radiologic cohort analysis of 48 cases with 1.7-years follow-up

Sign Up to like & get
recommendations!
Published in 2020 at "European Spine Journal"

DOI: 10.1007/s00586-020-06464-x

Abstract: Purpose To evaluate whether a new PEEK vertebral body replacement can maintain the sagittal alignment as an anterior column reconstruction device in thoracic and lumbar spinal defects due to trauma or tumor. Methods Retrospective review… read more here.

Keywords: anterior column; peek vertebral; body replacement; vertebral body ... See more keywords
Photo by ramaissance from unsplash

Motion preservation surgery for scoliosis with a vertebral body tethering system: a biomechanical study

Sign Up to like & get
recommendations!
Published in 2021 at "European Spine Journal"

DOI: 10.1007/s00586-021-07035-4

Abstract: There is a paucity of studies on new vertebral body tethering (VBT) surgical constructs especially regarding their potentially motion-preserving ability. This study analyses their effects on the ROM of the spine. Human spines (T10-L3) were… read more here.

Keywords: body tethering; one tether; vertebral body; rom ... See more keywords
Photo from wikipedia

Long-term clinical outcome of spinal Langerhans cell histiocytosis in children

Sign Up to like & get
recommendations!
Published in 2017 at "International Journal of Hematology"

DOI: 10.1007/s12185-017-2252-y

Abstract: Spinal involvement of Langerhans cell histiocytosis (LCH) affects morbidity, but outcomes are not well understood. We analyzed long-term outcomes following uniform treatment at a single institution. Clinical characteristics and outcomes of spinal LCH patients were… read more here.

Keywords: langerhans cell; term; long term; vertebral body ... See more keywords
Photo from wikipedia

Does pedicle screw fixation of the subaxial cervical spine provide adequate stabilization in a multilevel vertebral body fracture model? An in vitro biomechanical study

Sign Up to like & get
recommendations!
Published in 2018 at "Clinical Biomechanics"

DOI: 10.1016/j.clinbiomech.2018.02.009

Abstract: Background Cervical vertebral body fractures generally are treated through an anterior‐posterior approach. Cervical pedicle screws offer an alternative to circumferential fixation. This biomechanical study quantifies whether cervical pedicle screws alone can restore the stability of… read more here.

Keywords: reconstruction; pedicle; cervical pedicle; vertebral body ... See more keywords
Photo from wikipedia

The effect of vertebral body stapling on spine biomechanics and structure using a bovine model.

Sign Up to like & get
recommendations!
Published in 2020 at "Clinical biomechanics"

DOI: 10.1016/j.clinbiomech.2020.02.006

Abstract: BACKGROUND Adolescent idiopathic scoliosis is a common condition affecting 2.5% of the general population. Vertebral body stapling was introduced as a method of fusionless growth modulation for the correction of moderate idiopathic scoliosis (Cobb angles… read more here.

Keywords: biomechanics; effect vertebral; vertebral body; body stapling ... See more keywords
Photo by ramaissance from unsplash

Influence of endplate size and implant positioning of vertebral body replacements on biomechanics and outcome.

Sign Up to like & get
recommendations!
Published in 2020 at "Clinical biomechanics"

DOI: 10.1016/j.clinbiomech.2020.105251

Abstract: BACKGROUND Spinal stabilization by an anterior vertebral body replacement is frequently used in patients suffering from destroyed vertebral bodies. The aim of this study was to analyse (i) the choice of endplate size and positioning… read more here.

Keywords: biomechanics; endplate size; vertebral body; influence ... See more keywords
Photo from wikipedia

MRI-based synthetic CT of the lumbar spine: Geometric measurements for surgery planning in comparison with CT.

Sign Up to like & get
recommendations!
Published in 2021 at "European journal of radiology"

DOI: 10.1016/j.ejrad.2021.109999

Abstract: PURPOSE MRI is the imaging modality of choice for soft tissue-related spine disease. However, CT is superior to MRI in providing clear visualization of bony morphology. The purpose of this study is to test equivalency… read more here.

Keywords: mri based; lumbar spine; based synthetic; vertebral body ... See more keywords