Sign Up to like & get
recommendations!
1
Published in 2017 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.12129
Abstract: Abstract Volumetric‐modulated arc therapy (VMAT) treatment delivery requires three key dynamic components; gantry rotation, dose rate modulation, and multi‐leaf collimator motion, which are all simultaneously varied during the delivery. Misalignment of the gantry angle can…
read more here.
Keywords:
vmat;
gantry angle;
gantry;
time resolved ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2018 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.12398
Abstract: Abstract Purpose This study evaluates the benefit of a virtual bolus method for volumetric modulated arc therapy (VMAT) plan optimization to compensate breast modifications that may occur during breast treatment. Methods Ten files were replanned…
read more here.
Keywords:
virtual bolus;
breast;
treatment;
bolus ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2019 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.12688
Abstract: Abstract Purpose To investigate the fixed‐jaw intensity‐modulated radiotherapy (F‐IMRT) and tangential partial volumetric modulated arc therapy (tP‐VMAT) treatment plans for synchronous bilateral breast cancer (SBBC). Materials and method Twelve SBBC patients with pTis‐2N0M0 stages who…
read more here.
Keywords:
imrt tangential;
fixed jaw;
breast;
tangential partial ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2020 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.12878
Abstract: Abstract Purpose Volumetric modulated arc therapy (VMAT) is gaining popularity for stereotactic treatment of lung lesions for medically inoperable patients. Due to multiple beamlets in delivery of highly modulated VMAT plans, there are dose delivery…
read more here.
Keywords:
technique;
planning;
lung sbrt;
vmat plans ... See more keywords
Sign Up to like & get
recommendations!
2
Published in 2022 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.13519
Abstract: Abstract Purpose The dual‐layer multi‐leaf collimator (MLC) in Halcyon involves further complexities in the dose calculation process, because the leaf‐tip transmission varies according to the leaf trailing pattern. For the volumetric modulated arc therapy (VMAT)…
read more here.
Keywords:
dose calculation;
layer;
vmat;
leaf ... See more keywords
Sign Up to like & get
recommendations!
2
Published in 2022 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.13598
Abstract: Abstract Purpose To provide plan backup resiliency for patients treated on a solitary high definition multileaf collimator (HDMLC) linac by developing a fully integrated Eclipse script, which converts patient plans initially optimized on Millennium‐120 (M120)…
read more here.
Keywords:
hdmlc;
geometry;
millennium 120;
vmat ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.14415
Abstract: Abstract Background Intracranial stereotactic radiosurgery (SRS) aims at achieving highly conformal dose distribution and, at the same time, attaining rapid dose falloff outside the treatment target. SRS is performed using different techniques including dynamic conformal…
read more here.
Keywords:
vmat;
dca vmat;
dose conformity;
conformity ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.14479
Abstract: Abstract Purpose This study aims to introduce modified fixed field volumetric modulated arc therapy (MF‐VMAT) which manually opened the field size by fixing the jaws and comparing it to the typical planning technique, auto field…
read more here.
Keywords:
field;
treatment;
vmat;
cervical cancer ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2025 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.70257
Abstract: Abstract Purpose This study aimed to comprehensively compare the dosimetric characteristics of three different radiotherapy techniques—hybrid intensity‐modulated radiotherapy (hy‐IMRT), tangential volumetric‐modulated arc therapy (t‐VMAT), and continuous volumetric‐modulated arc therapy (c‐VMAT)—used after breast‐conserving surgery for left‐sided…
read more here.
Keywords:
left sided;
vmat;
conserving surgery;
breast conserving ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2025 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.70282
Abstract: Abstract Introduction Linac‐based SRS provides a highly precise noninvasive treatment option for intracranial lesions. DCA and VMAT are commonly used Linac‐based techniques. There are no standardized guidelines for technique selection, particularly considering the geometric properties…
read more here.
Keywords:
vmat;
decision making;
based srs;
geometry ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2025 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.70313
Abstract: Abstract Background Radiotherapy techniques have advanced significantly over the past few decades. Whole‐brain radiotherapy combined with a simultaneous integrated boost (WBRT+SIB) is increasingly used to treat limited brain metastases. Purpose To retrospectively compare helical tomotherapy…
read more here.
Keywords:
brain;
vmat;
whole brain;
tomotherapy ... See more keywords