Articles with "zno pva" as a keyword



A ZnO/PVA/PAADDA composite electrode for rechargeable zinc-air battery

Sign Up to like & get
recommendations!
Published in 2017 at "Ionics"

DOI: 10.1007/s11581-017-2150-6

Abstract: A ZnO/PVA/PAADDA composite electrode for rechargeable zinc-air battery was prepared by chemical cross-linked PVA (polyvinyl alcohol) with poly(acrylamide-co-diallyldimethylammonium chloride) (PAADDA). Fourier transform infrared spectra (FT-IR), scanning electron microscopy (SEM), and transmission microscopy (TEM) studies reveal… read more here.

Keywords: pva paadda; microscopy; paadda composite; electrode ... See more keywords
Photo from wikipedia

An antifouling impedimetric sensor based on zinc oxide embedded polyvinyl alcohol nanoplatelets for wide range dopamine determination in the presence of high concentration ascorbic acid.

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of pharmaceutical and biomedical analysis"

DOI: 10.1016/j.jpba.2021.114278

Abstract: Dopamine determination is of great importance for the early diagnosis of neurological diseases. However, dopamine sensors mostly encounter important challenges such as surface fouling and interference of co-existing biochemicals. Here, nanoplatelets of zinc oxide embedded… read more here.

Keywords: zno pva; determination; dopamine determination;

Preparation of ZnO/PVA flexible piezoelectric films for sensing dynamic-static superimposed loads under varying temperatures

Sign Up to like & get
recommendations!
Published in 2025 at "Scientific Reports"

DOI: 10.1038/s41598-025-25644-7

Abstract: Flexible thin-film sensors exhibit considerable application potential in the structural health monitoring of bridges under complex traffic scenarios, owing to their capability of rapidly responding to dynamic loads, static loads, and dynamic-static coupled loads. In… read more here.

Keywords: zno pva; flexible piezoelectric; zno; dynamic static ... See more keywords

Saraca asoca extract mediated ZnO/PVA nanocomposite coatings for orthopaedic implants

Sign Up to like & get
recommendations!
Published in 2025 at "Surface Engineering"

DOI: 10.1177/02670844251333602

Abstract: Orthopaedic implants commonly use titanium and its alloys because of their superior mechanical properties, corrosion resistance and biocompatibility. However, these metal implants have limited application, hindered by poor osseointegration and the potential risk of implant-associated… read more here.

Keywords: nanocomposite coatings; pva nanocomposite; zno pva; pva ... See more keywords